Skip to main content
Siemens 3RT1046-3AL20-ZX95 — Contactors

Siemens 3RT1046-3AL20-ZX95 SIRIUS Power Contactor, 55 kW at

MPN3RT1046-3AL20-ZX95

Siemens SIRIUS, power contactor, S3 frame, 3RT1046-3AL20-ZX95, 55 kW at 500 V AC-3, screw terminals, DIN rail mount, 146 x 70 x 139 mm.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1046-3AL20-ZX95 — Identification
ParameterValue
Contactor frame sizeS3
3RT1046-3AL20-ZX95 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V80 A
Rated value @ 400 V3 A
Rated value @ 500 V55 kW
Rated value @ 690 V25.4 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1046-3AL20-ZX95 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz230 V
3RT1046-3AL20-ZX95 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1046-3AL20-ZX95 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 250 A
Short-circuit coordination type 2, fusefuse gL/gG: 160 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1046-3AL20-ZX95 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, solid or stranded2x (2.5 ... 16 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm and 75 mm standard mounting rail
Side-by-side mountingYes
3RT1046-3AL20-ZX95 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1046-3AL20-ZX95 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1046-3AL20-ZX95 — Mechanical
ParameterValue
Width70 mm
Height146 mm
Depth139 mm
3RT1046-3AL20-ZX95 — Specifications
ParameterValue
At AC10 ... 25 ms

Product details

SIRIUS S3 power contactor — 55 kW at 500 V, current production

The 3RT1046-3AL20-ZX95: Dimensions are 146 mm high, 70 mm wide, 139 mm deep — that 70 mm width is the S3 frame footprint, and it snap-mounts onto 35 mm or 75 mm DIN rail (screw and snap-on mounting).

Terminal wiring — screw-type, two-wire capacity

Solid wire range: 2x (0.25 to 2.5 mm²) for the smaller terminals, and 2x (2.5 to 16 mm²) for the larger ones. Stranded wire goes up to 2x (10 to 50 mm²) on the main power terminals. That's a two-wire-per-clamp design — you can land two conductors of the same size under one screw, which saves a terminal block row in the panel.

Switching frequency and duty-cycle limits

Maximum switching rates per duty class: 900 operations per hour at AC-1 (resistive loads), 350/h at AC-2 (slip-ring motors), 850/h at AC-3 (squirrel-cage motors), and 250/h at AC-4 (plugging/inching).

Environmental and mounting notes

Frequently asked questions

Where can I buy 3RT1046-3AL20-ZX95 and how do I get a price?

This part is sourced to order against an RFQ through independent distribution. Submit a quote request for current availability and pricing.

What is 3RT1046-3AL20-ZX95's listed depth?

The depth is 139 mm.

What wire sizes does the 3RT1046-3AL20-ZX95 accept on the main terminals?

Solid wire: 2x (0.25 to 2.5 mm²) for smaller terminals, 2x (2.5 to 16 mm²) for larger. Stranded: 2x (10 to 50 mm²) on the main power terminals. All screw-type.

Will 3RT1046-3AL20-ZX95 drop into a panel specified around 3RT1044-1FB46 without rewiring?

Both are SIRIUS S3 frame contactors with the same 70 mm width and DIN rail mounting, so the mechanical footprint is identical. Terminal layout and wire ranges are similar (screw-type, two-wire capacity). Electrical ratings differ — verify the load current against the 3RT1046's AC-3 rating before swapping.

MPN
3RT1046-3AL20-ZX95