Skip to main content
Siemens 3RT1054-1AR36 — Contactors

Siemens 3RT1054-1AR36 SIRIUS Power Contactor, Size S6, 440-4

MPN3RT1054-1AR36
Active

Siemens SIRIUS power contactor, Size S6, 3RT1054-1AR36, rated 440-480 V, screw-type coil terminals, auxiliary switch, 170 mm depth.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RT1054-1AR36 — Identification
ParameterValue
Contactor frame sizeS6
3RT1054-1AR36 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V97 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V25 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1054-1AR36 — Control & Coil
ParameterValue
Control supply voltage typeAC/DC
Rated value @ 50 Hz0.8
Rated value @ 50 Hz440 ... 480 V
3RT1054-1AR36 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1054-1AR36 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 355 A (690 V, 100 kA)
Short-circuit coordination type 2, fusegG: 250 A (690 V, 100 kA), aM: 200 A (690 V, 50 kA), BS88: 250 A (415 V, 50 kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT1054-1AR36 — Connection & Mounting
ParameterValue
Main circuit connectionbox terminal
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew fixing
Side-by-side mountingYes
3RT1054-1AR36 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1054-1AR36 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1054-1AR36 — Mechanical
ParameterValue
Width120 mm
Height172 mm
Depth170 mm
3RT1054-1AR36 — Specifications
ParameterValue
At AC40 ... 60 ms

Product details

Siemens SIRIUS 3RT1054-1AR36 — Size S6 Power Contactor

It carries a rated voltage of 440 to 480 V and comes with an integrated auxiliary switch, screw-type coil terminals, and a screw fixing mount — the standard panel-mount approach for this frame class.

The contactor's AC-3 switching frequency is rated at 1 000 operations per hour — that's the standard motor-starting duty cycle for conveyors, pumps, and fans. AC-4 drops to 130 ops/h, which covers plugging and inching applications where the motor is reversed or jogged under load. Auxiliary contact ratings are provided at various voltages: 10 A at 24 V, 2 A at 48 V and 60 V, 1 A at 110 V, 0.9 A at 125 V, and 0.3 A at 220 V. These are the make/break limits for the built-in auxiliary switch — useful for interlocking or status feedback without adding a separate block.

Dimensions: 172 mm high, 120 mm wide, 170 mm deep. Power circuit wiring accepts stranded conductors from 16 to 70 mm². The coil terminals are screw-type, accepting solid or stranded wire: 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or max 2x (0.75 to 4 mm²). That covers most control-circuit cable sizes in a standard panel.

Environmental and Operating Limits

The storage limit is broader because the contactor is not under load — that's the handling and shelf-life spec, not the running limit.

Frequently asked questions

Where can I buy 3RT1054-1AR36?

This part is available to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the closest functional second-source to 3RT1054-1AR36?

The 3RT1054-1AB36 is a direct sibling in the same Size S6 frame — same dimensions and mounting footprint, so it drops into the same panel without rewiring. The difference is the coil voltage; the -1AR36 has a 440-480 V coil, while the -1AB36 has a different coil voltage. Verify coil voltage compatibility before substituting.

What is the depth of 3RT1054-1AR36?

The depth is 170 mm.

What wire sizes does 3RT1054-1AR36 accept on the power circuit?

The power terminals accept stranded conductors from 16 to 70 mm².

Will 3RT1054-1AR36 drop into a panel specified around 3RT1054-1AB36?

Yes — both are Size S6 contactors with identical dimensions and mounting pattern. The only difference is the coil voltage rating, so as long as the coil voltage matches your control circuit, it's a direct swap.

MPN
3RT1054-1AR36