Siemens 3RT1054-3AV36 SIRIUS Power Contactor, 380-420V Coil,

MPN3RT1054-3AV36
Active

Siemens SIRIUS power contactor, size S6, 3RT1054-3AV36, 380-420 V AC coil, spring-type terminals, screw fixing, 172 x 120 x 170 mm.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1054-3AV36 — Identification
ParameterValue
Contactor frame sizeS6
3RT1054-3AV36 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V97 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V25 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1054-3AV36 — Control & Coil
ParameterValue
Control supply voltage typeAC/DC
Rated value @ 50 Hz0.8
Rated value @ 50 Hz380 ... 420 V
3RT1054-3AV36 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1054-3AV36 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 355 A (690 V, 100 kA)
Short-circuit coordination type 2, fusegG: 250 A (690 V, 100 kA), aM: 200 A (690 V, 50 kA), BS88: 250 A (415 V, 50 kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT1054-3AV36 — Connection & Mounting
ParameterValue
Main circuit connectionbox terminal
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, solid or stranded2x (0,25 ... 2,5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Mounting methodscrew fixing
Side-by-side mountingYes
3RT1054-3AV36 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1054-3AV36 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1054-3AV36 — Mechanical
ParameterValue
Width120 mm
Height172 mm
Depth170 mm
3RT1054-3AV36 — Specifications
ParameterValue
At AC40 ... 60 ms

Product details

It carries a 380-420 V AC coil and uses spring-type terminals on the magnet coil, with screw fixing for panel mounting. The contactor includes an auxiliary switch. Arcing time is 10-15 ms, and operating times are 40-60 ms for both AC and DC.

The coil is rated 380-420 V AC, which is a standard European 400 V line voltage. If your control voltage differs, you'll need a different coil variant — this is not a universal coil contactor. Switching frequency varies by duty: up to 1,000 operations per hour at AC-3 (motor starting), 800 at AC-1 (resistive), 400 at AC-2 (slip-ring motors), and 130 at AC-4 (plugging/inching). The AC-3e rating matches the AC-3 figure.

Mounting is by screw fixing, not snap-on DIN rail. Power terminals accept stranded wire 16-70 mm². The auxiliary / coil terminals accept solid or stranded 2x (0.25-2.5 mm²). Spring-type terminals on the magnet coil mean no screw torqueing on the coil connection — just strip and insert.

MPN