Siemens 3RT1054-6AD36 SIRIUS Power Contactor, S6

MPN3RT1054-6AD36
Active

Siemens SIRIUS 3RT1054-6AD36 power contactor, S6 frame size, 120 mm width, 170 mm depth, 42-48 V rated control supply voltage, screw-type coil terminals, auxiliary switch included.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RT1054-6AD36 — Identification
ParameterValue
Contactor frame sizeS6

Ratings & Performance

3RT1054-6AD36 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V97 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V25 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A

Control & Coil

3RT1054-6AD36 — Control & Coil
ParameterValue
Control supply voltage typeAC/DC
Rated value @ 50 Hz0.8
Rated value @ 50 Hz42 ... 48 V

Contacts & Poles

3RT1054-6AD36 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)

Protection & Coordination

3RT1054-6AD36 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 355 A (690 V, 100 kA)
Short-circuit coordination type 2, fusegG: 250 A (690 V, 100 kA), aM: 200 A (690 V, 50 kA), BS88: 250 A (415 V, 50 kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)

Connection & Mounting

3RT1054-6AD36 — Connection & Mounting
ParameterValue
Main circuit connectionConnection bar
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew fixing
Side-by-side mountingYes

Durability

3RT1054-6AD36 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000

Environmental

3RT1054-6AD36 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m

Mechanical

3RT1054-6AD36 — Mechanical
ParameterValue
Width120 mm
Height172 mm
Depth170 mm

Specifications

3RT1054-6AD36 — Specifications
ParameterValue
At AC40 ... 60 ms

Product details

Sizing the power path for the S6 frame

The 3RT1054-6AD36: This is a SIRIUS S6-frame power contactor — the largest standard frame in the SIRIUS contactor family, sized for heavy motor and resistive loads where the main power conductors run 25 to 120 mm² stranded. The 120 mm width and 172 mm height mean it fills a full-width slot on a DIN-rail or backplate; plan the enclosure layout around that footprint, not a smaller S3 or S0. The main pole termination accepts 25–120 mm² stranded copper — that's a single cable up to 4/0 AWG or two parallel runs.

Switching duty and operating cycle limits

If your application cycles faster than these limits, the contactor will overheat and fail early — plan for a larger frame or a different switching topology. That's typical for a contactor this size — the operator will see a 50–70 ms delay from the PLC output turning on to the motor actually starting.

Mounting position and clearance requirements

Mounting is by screw fixing through 9 mm diameter holes. Those are the minimum air gaps to adjacent metalwork or other devices; crowding them reduces arc-quenching performance.

Environmental limits for storage and operation

If the panel ambient exceeds 60 °C at full load, the contactor needs derating or forced ventilation — the datasheet's thermal derating curve (not reproduced here) governs the actual continuous current at elevated temperatures.

Auxiliary contact ratings and control supply

The contactor includes an auxiliary switch. These are the make/break capacities for the auxiliary contacts — if your PLC output drives a 48 VDC auxiliary load above 2 A, you need an interposing relay.