Siemens 3RT1054-6AP36-ZX95 — Contactors

Siemens 3RT1054-6AP36-ZX95 SIRIUS Power Contactor, Size S6

MPN3RT1054-6AP36-ZX95
Active

Siemens SIRIUS 3RT1054-6AP36-ZX95 power contactor, Size S6, 220-240 V AC 50/60 Hz coil, screw-type coil terminals, screw fixing, 170 x 120 x 172 mm (DxWxH).

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RT1054-6AP36-ZX95 — Identification
ParameterValue
Contactor frame sizeS6

Ratings & Performance

3RT1054-6AP36-ZX95 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V97 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V25 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A

Control & Coil

3RT1054-6AP36-ZX95 — Control & Coil
ParameterValue
Control supply voltage typeAC/DC
Rated value @ 50 Hz0.8
Rated value @ 50 Hz220 ... 240 V

Contacts & Poles

3RT1054-6AP36-ZX95 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)

Protection & Coordination

3RT1054-6AP36-ZX95 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 355 A (690 V, 100 kA)
Short-circuit coordination type 2, fusegG: 250 A (690 V, 100 kA), aM: 200 A (690 V, 50 kA), BS88: 250 A (415 V, 50 kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)

Connection & Mounting

3RT1054-6AP36-ZX95 — Connection & Mounting
ParameterValue
Main circuit connectionConnection bar
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew fixing
Side-by-side mountingYes

Durability

3RT1054-6AP36-ZX95 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000

Environmental

3RT1054-6AP36-ZX95 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m

Mechanical

3RT1054-6AP36-ZX95 — Mechanical
ParameterValue
Width120 mm
Height172 mm
Depth170 mm

Specifications

3RT1054-6AP36-ZX95 — Specifications
ParameterValue
At AC40 ... 60 ms

Product details

SIRIUS S6 frame — what the ratings mean for the panel

The 3RT1054-6AP36-ZX95 is a SIRIUS-branded power contactor in the S6 frame size, designed for screw fixing to a mounting surface — not DIN-rail snap-on, so plan for drilled and tapped backplate or a sub-panel adapter. Coil is rated 220-240 V AC at 50/60 Hz with a pickup power factor of 0.8 (initial and holding), meaning the inrush current is higher than a DC-coil equivalent — factor this into the control transformer sizing if multiple contactors pick up simultaneously. Mechanical endurance is 10 million operations typical, but the electrical life depends heavily on the duty class: at AC-3 (standard motor switching) the contactor is rated for 1,000 switching cycles per hour, while AC-4 (plugging/inching) drops to 130 cycles per hour — the AC-4 ceiling is the real limiter for reversing or jogging applications.

Termination and wiring — main poles and auxiliary

Main power conductors terminate with stranded wire from 25 to 120 mm² — that covers everything from a 35 mm² feed to a 95 mm² motor cable, but the lug type (ring or fork) is not specified; expect to supply your own compression lugs for the larger sizes. Auxiliary and control wiring accepts solid or stranded conductors: 2x 0.5-1.5 mm² or 2x 0.75-2.5 mm² per terminal, max 2x 4 mm² — the screw terminals are shared between the coil and any add-on auxiliary switch block. The coil itself terminates via screw-type terminals, not quick-connects — this is standard for the S6 frame but means the control wiring must be stripped and torqued, not pushed on.

Mounting clearances and orientation

Mounting position allows vertical surface with +/-90° rotation and +/-22.5° tilt forward/back — so the contactor can be mounted on its side or at a slight angle, but not inverted (no upside-down mounting is listed). Minimum clearances to adjacent metalwork: 10 mm upwards, 10 mm downwards, 10 mm at the sides, and 20 mm forwards — the forward clearance is the tightest and matters most for arc-chamber venting; crowding the front face reduces the arc-quenching margin.

Auxiliary contact ratings and switching performance

The contactor includes an auxiliary switch (built-in or add-on — the listing confirms presence but not the contact configuration). Rated switching currents: 10 A at 24 V, 2 A at 48/60 V, 1 A at 110 V, 0.9 A at 125 V, and 0.3 A at 220 V — these are the make/break capacities for the auxiliary contacts, not the main poles. Arcing time is 10-15 ms, and total operating time (both AC and DC coil) is 40-60 ms — the arcing time is short enough that a standard PLC scan cycle (10-20 ms) may miss a contact bounce event; use a 50 ms debounce on the feedback input if the auxiliary contact signals the main pole state.

Environmental limits and storage

Operating ambient temperature range is -25 to +60 °C, storage range is -55 to +80 °C — the -25 °C low end is fine for most indoor panels but marginal for unheated outdoor enclosures in northern climates; if the panel sees -30 °C, the contactor must be kept powered or heated.

MPN
3RT1054-6AP36-ZX95