Skip to main content
Siemens 3RT1054-6NP38-0PA5 — Contactors

3RT1054-6NP38-0PA5 - Siemens

MPN3RT1054-6NP38-0PA5

Power contactor, AC-3 115 A, 55 kW / 400 V AC/DC operation 200-277 V UC Auxiliary contacts 2 NO + 2 NC solid-state-compatible, 3-pole, Size S6, Busbar connections, Drive: electronic, with PLC interface 24 V DC

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RT1054-6NP38-0PA5 — Identification
ParameterValue
Contactor frame sizeS6
3RT1054-6NP38-0PA5 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V97 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V25 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1054-6NP38-0PA5 — Control & Coil
ParameterValue
Control supply voltage typeAC/DC
Rated value @ 50 Hz0.6
Rated value @ 50 Hz200 ... 277 V
3RT1054-6NP38-0PA5 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1054-6NP38-0PA5 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 355 A (690 V, 100 kA)
Short-circuit coordination type 2, fusegG: 250 A (690 V, 100 kA), aM: 200 A (690 V, 50 kA), BS88: 250 A (415 V, 50 kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT1054-6NP38-0PA5 — Connection & Mounting
ParameterValue
Main circuit connectionConnection bar
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew fixing
Side-by-side mountingYes
3RT1054-6NP38-0PA5 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1054-6NP38-0PA5 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1054-6NP38-0PA5 — Mechanical
ParameterValue
Width120 mm
Height172 mm
Depth170 mm
3RT1054-6NP38-0PA5 — Specifications
ParameterValue
At AC80 ... 90 ms

Frequently asked questions

What is the coil voltage of Siemens 3RT1054-6NP38-0PA5?

Buyers must confirm the 200-277 V UC AC/DC coil range matches their control supply before purchase.

What does the -0PA5 suffix mean on a Siemens 3RT10 contactor?

The option code defines the PLC interface 24 V DC and busbar connections; misreading it leads to wrong part ordered.

Is the 3RT1054-6NP38-0PA5 suitable for solid-state relay interfacing?

The 2 NO + 2 NC auxiliary contacts are specified as solid-state-compatible, critical for low-current PLC I/O.

What replacement fits a Siemens 3RT1054-6NP38-0PA5?

Identifies direct cross-references and functionally equivalent S6 contactors when stock is constrained.

What is the difference between 3RT1054 and 3RT1055 contactors?

Differentiates the 55 kW (115 A) and 75 kW (150 A) ratings so buyers do not over- or under-size.

Where can I buy 3RT1054-6NP38-0PA5 with current stock and price?

Captures bottom-funnel buyers comparing authorized stockists and lead times for this MPN.

MPN
3RT1054-6NP38-0PA5