Skip to main content
Siemens 3RT1054-6XJ46-0LA2 — Contactors

Siemens SIRIUS 3RT1054-6XJ46-0LA2 Power Contactor, S6 Frame

MPN3RT1054-6XJ46-0LA2
Active

Siemens SIRIUS power contactor, S6 frame size, DC operated, auxiliary contacts, screw fixing, 170 mm depth, 120 mm width, 172 mm height.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1054-6XJ46-0LA2 — Identification
ParameterValue
Contactor frame sizeS6
3RT1054-6XJ46-0LA2 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V97 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V48 kW
Rated value @ 230 V25 hp
Rated value @ 24 V6 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1054-6XJ46-0LA2 — Control & Coil
ParameterValue
Control supply voltage typeDC
3RT1054-6XJ46-0LA2 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
3RT1054-6XJ46-0LA2 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 355 A (690 V, 100 kA)
Short-circuit coordination type 2, fusegG: 315 A (690 V, 100 kA), aM: 200 A (690 V, 50 kA), BS88: 250 A (415 V, 50 kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT1054-6XJ46-0LA2 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew fixing
Side-by-side mountingYes
3RT1054-6XJ46-0LA2 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1054-6XJ46-0LA2 — Environmental
ParameterValue
Operating temperature range-40 ... +70 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1054-6XJ46-0LA2 — Mechanical
ParameterValue
Width120 mm
Height172 mm
Depth170 mm

Product details

SIRIUS S6 power contactor — DC coil, auxiliary contacts onboard

The 3RT1054-6XJ46-0LA2: Rated for 6 A at 24 V DC on the auxiliary circuit, the contactor also handles 2 A at 48 V DC, 2 A at 60 V DC, 1 A at 110 V DC, and 0.9 A at 125 V DC — covering control voltages common across European and North American panels.

Switching frequency and duty cycle ratings

Maximum switching frequency varies by duty class: 800 operations/hour in AC-1 (resistive loads), 400/h in AC-2 (slip-ring motors), 1,000/h in AC-3 (squirrel-cage motors — the most common motor-starting category), and 130/h in AC-4 (plugging/reversing). DC switching frequencies: 400/h for DC-1 (resistive), 500/h for DC-3 (shunt motors), and 500/h for DC-5 (series motors). AC-3e rating matches AC-3 at 1,000/h.

Fastening is screw fixing (not DIN rail), with a single 9 mm mounting hole. The contactor measures 172 mm high, 120 mm wide, and 170 mm deep — the S6 frame is a substantial footprint that needs planning in the panel layout. Terminal capacity accepts solid or stranded conductors: 2x 0.5 to 1.5 mm², 2x 0.75 to 2.5 mm², and up to 2x 0.75 to 4 mm² — covers standard control wiring in both metric and AWG equivalents.

Frequently asked questions

What are the key dimensions of this contactor?

Height is 172 mm, width is 120 mm, and depth is 170 mm. It uses screw fixing with one 9 mm mounting hole.

What auxiliary contact ratings does this contactor carry?

The auxiliary switch is rated 6 A at 24 V DC, 2 A at 48 V DC, 2 A at 60 V DC, 1 A at 110 V DC, and 0.9 A at 125 V DC.

Where can I buy 3RT1054-6XJ46-0LA2 and how is it quoted?

This contactor is sourced through independent distribution. Availability and current pricing are confirmed at quote time against an RFQ — no stock figures or lead-time numbers are published here.

What is the mechanical life of this SIRIUS contactor?

Typical mechanical life is 10,000,000 operations, consistent with the S6 frame design for high-cycle industrial applications.

What wire sizes does the terminal block accept?

It accepts 2x 0.5 to 1.5 mm², 2x 0.75 to 2.5 mm², and up to 2x 0.75 to 4 mm² solid or stranded conductors.

MPN
3RT1054-6XJ46-0LA2