power contactor, AC-3e/AC-3 150 A, 75 kW / 400 V AC (50-60 Hz) / DC Uc: 500-550 V 3-pole, auxiliary contacts 2 NO + 2 NC drive: conventional main circuit: busbar control and auxiliary circuit: spring-loaded terminal
Specifications
| Parameter | Value |
|---|---|
| Contactor frame size | S6 |
| Parameter | Value |
|---|---|
| Rated operational current, AC-12, max. | 10 A |
| Rated operational current, AC-4 @ 400 V | 132 A |
| Rated value @ 400 V | 3 A |
| Rated value @ 500 V | 2 A |
| Rated value @ 690 V | 1 A |
| Rated value @ 230 V | 30 hp |
| Rated value @ 24 V | 10 A |
| Rated value @ 60 V | 2 A |
| Rated value @ 110 V | 1 A |
| Rated value @ 220 V | 0.3 A |
| Parameter | Value |
|---|---|
| Control supply voltage type | AC/DC |
| Rated value @ 50 Hz | 0.8 |
| Rated value @ 50 Hz | 500 ... 550 V |
| Parameter | Value |
|---|---|
| Main poles | 3 |
| Main NO contacts | 3 |
| Auxiliary contact reliability | 1 faulty switching per 100 million (17 V, 1 mA) |
| Parameter | Value |
|---|---|
| Short-circuit coordination type 1, fuse | gG: 355 A (690 V, 100 kA) |
| Short-circuit coordination type 2, fuse | gG: 315 A (690 V, 100 kA), aM: 200 A (690 V, 50 kA), BS88: 315 A (415 V, 50 kA) |
| Aux. switch short-circuit protection, fuse | gG: 10 A (500 V, 1 kA) |
| Parameter | Value |
|---|---|
| Main circuit connection | Connection bar |
| Aux. / control circuit connection | spring-loaded terminals |
| Conductor cross-section, solid | 2x (0.25 ... 2.5 mm²) |
| Conductor cross-section, solid or stranded | 2x (0,25 ... 2,5 mm²) |
| Conductor cross-section, finely stranded w/ ferrule | 2x (0.25 ... 1.5 mm²) |
| Mounting method | screw fixing |
| Side-by-side mounting | Yes |
| Parameter | Value |
|---|---|
| Durability (operating cycles, typ.) | 10 000 000 |
| Durability with aux. switch block (cycles, typ.) | 10 000 000 |
| Parameter | Value |
|---|---|
| Operating temperature range | -25 ... +60 °C |
| Storage temperature range | -55 ... +80 °C |
| Installation altitude, max. | 2 000 m |
| Parameter | Value |
|---|---|
| Width | 120 mm |
| Height | 172 mm |
| Depth | 170 mm |
| Parameter | Value |
|---|---|
| At AC | 40 ... 60 ms |
Frequently asked questions
What is the coil voltage of Siemens 3RT1055-2AS36?
Buyers must match coil (Uc) to their control supply before ordering to avoid return/installation delays.
What are the main specifications of the 3RT1055-2AS36 contactor?
Engineers need the AC-3e 150 A / 75 kW rating, pole count, and terminal type to confirm fit for the motor load.
How many auxiliary contacts does the 3RT1055-2AS36 have?
Wiring design depends on the exact 2 NO + 2 NC auxiliary contact configuration for interlock and signaling circuits.
Is the 3RT1055-2AS36 suitable for AC-3e applications?
AC-3e compliance is required for modern IE3/IE4 motors and affects panel certification.
What is the difference between 3RT1055-2AS36 and 3RT1055-2AF36?
Comparing the AS36 vs AF36 coil variants prevents misorders and helps select the correct 500-550 V vs other Uc part.
Where can I buy 3RT1055-2AS36 with current stock and pricing?
A live price/stock and authorized-distributor link is the primary conversion path for a long-tail MPN.