Siemens 3RT1055-6AB36 SIRIUS Power Contactor, Size S6

MPN3RT1055-6AB36
Active

Siemens SIRIUS 3RT1055-6AB36 power contactor, Size S6, 172 x 120 x 170 mm, screw fixing, main circuit 25-120 mm² stranded, coil 23-26 V screw terminals.

$274.32Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RT1055-6AB36 — Identification
ParameterValue
Contactor frame sizeS6
3RT1055-6AB36 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V132 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V30 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1055-6AB36 — Control & Coil
ParameterValue
Control supply voltage typeAC/DC
Rated value @ 50 Hz0.8
Rated value @ 50 Hz23 ... 26 V
3RT1055-6AB36 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1055-6AB36 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 355 A (690 V, 100 kA)
Short-circuit coordination type 2, fusegG: 315 A (690 V, 100 kA), aM: 200 A (690 V, 50 kA), BS88: 315 A (415 V, 50 kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT1055-6AB36 — Connection & Mounting
ParameterValue
Main circuit connectionConnection bar
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew fixing
Side-by-side mountingYes
3RT1055-6AB36 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1055-6AB36 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1055-6AB36 — Mechanical
ParameterValue
Width120 mm
Height172 mm
Depth170 mm
3RT1055-6AB36 — Specifications
ParameterValue
At AC40 ... 60 ms

Product details

S6 frame, 172 x 120 x 170 mm — panel fit and conductor sizing

The 3RT1055-6AB36: That footprint lands it in the larger contactor bracket — plan for a panel depth of at least 190 mm to clear the rear arc chamber and wiring gutters. Main power circuit accepts stranded conductors from 25 mm² up to 120 mm². That range covers everything from a 50 mm² motor feed to a 95 mm² distribution bus — the lug well is sized for the full cross-section, so no adapter needed for the upper end. That's standard control wiring — 1.5 mm² for signal runs, 2.5 mm² for interposing relay feeds. Mounting is by screw fixing through a single 9 mm hole per the S6 pattern.

Coil 23-26 V screw terminals, switching rates per duty class

The magnet coil is rated 23-26 V with screw-type terminals. That's a narrow-band DC coil — confirm your control supply sits inside that window; a 24 V nominal rail with 5% tolerance (22.8-25.2 V) is fine, but a 24 V rail with 10% droop under load dips to 21.6 V and risks drop-out. Operating times are 40-60 ms for both AC and DC coil supply. Arcing time runs 10-15 ms. For sequencing logic, budget 70 ms from coil energisation to main contact closure — the PLC scan cycle needs to account for that window if you're interlocking with another device. Maximum switching rates vary by duty: AC-1 (resistive) 800 cycles/hour, AC-3 (motor start/run) 750 cycles/hour, AC-2 (slip-ring motor) 300 cycles/hour, AC-4 (plugging/inching) 130 cycles/hour. For a conveyor running AC-3 duty at 750 ops/h, that's one start every 4.8 seconds — the contactor is rated for that cadence without accelerated wear.

Auxiliary contact ratings and thermal clearance

The contactor ships with an auxiliary switch block. That derating curve is typical for DC switching — the arc extinguishes slower at higher voltage, so the contact gap limits the current. For a 24 VDC PLC input circuit, the 10 A rating gives generous headroom. Those are the free-air gaps needed for natural convection cooling — stacking contactors tighter than that derates the thermal capacity. In a sealed enclosure with restricted airflow, increase the side gaps to 20 mm. The -25 °C floor means it's fine for unheated plant rooms in temperate climates, but not for freezer applications without a heater.

Lifecycle and sourcing — active production, quoted to order

Mechanical endurance is 10,000,000 typical cycles. That's the contactor frame life — the electrical endurance at rated AC-3 current will be lower, but the mechanical figure tells you the actuator and spring set are built for high-cycle applications like conveyor sortation or pump cycling.

Frequently asked questions

What are the main circuit conductor size limits for 3RT1055-6AB36?

The main power circuit accepts stranded copper conductors from 25 mm² up to 120 mm².