Siemens 3RT1056-2AD36 — Contactors

3RT1056-2AD36 - Siemens

MPN3RT1056-2AD36
Active

power contactor, AC-3e/AC-3 185 A, 90 kW / 400 V AC (50-60 Hz) / DC Uc: 42-48 V 3-pole, auxiliary contacts 2 NO + 2 NC drive: conventional main circuit: busbar control and auxiliary circuit: spring-loaded terminal

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RT1056-2AD36 — Identification
ParameterValue
Contactor frame sizeS6
3RT1056-2AD36 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V160 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V30 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1056-2AD36 — Control & Coil
ParameterValue
Control supply voltage typeAC/DC
Rated value @ 50 Hz0.8
Rated value @ 50 Hz42 ... 48 V
3RT1056-2AD36 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1056-2AD36 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 355 A (690 V, 100 kA)
Short-circuit coordination type 2, fusegG: 315 A (690 V, 100 kA), aM: 200 A (690 V, 50 kA), BS88: 315 A (415 V, 50 kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT1056-2AD36 — Connection & Mounting
ParameterValue
Main circuit connectionConnection bar
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, solid or stranded2x (0,25 ... 2,5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Mounting methodscrew fixing
Side-by-side mountingYes
3RT1056-2AD36 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1056-2AD36 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1056-2AD36 — Mechanical
ParameterValue
Width120 mm
Height172 mm
Depth170 mm
3RT1056-2AD36 — Specifications
ParameterValue
At AC40 ... 60 ms

Frequently asked questions

What are the specifications of the Siemens 3RT1056-2AD36 contactor?

Engineers and buyers need full electrical and mechanical specs to confirm fit for motor load and panel layout.

What coil voltage does the 3RT1056-2AD36 use?

A 42-48 V DC coil must match the control circuit; wrong coil voltage prevents operation or damages the contactor.

Is the 3RT1056-2AD36 suitable for AC-3e applications?

AC-3e rating determines if the contactor handles modern IE3/IE4 motors with regenerative braking duty cycles.

What is the difference between 3RT1056 and 3RT1055 contactors?

Designers comparing frame sizes need to know current and kW ratings to avoid undersizing the contactor.

What is the price and current stock of the 3RT1056-2AD36?

Sourcing decisions and quote requests depend on live pricing and authorized-channel availability.

Where can I buy a direct replacement or cross-reference for the 3RT1056-2AD36?

Buyers facing lead-time risk need verified substitutes that match 185 A, 2 NO + 2 NC, and spring terminals.

MPN
3RT1056-2AD36