Siemens 3RT1064-2AB36 — Contactors

Siemens 3RT1064-2AB36 SIRIUS S10 Power Contactor, 70-240 mm²

MPN3RT1064-2AB36
Active

Siemens SIRIUS S10 power contactor, 3RT1064-2AB36, size S10, main terminals 70-240 mm² stranded, auxiliary 2x 0.25-2.5 mm², screw fixing, 202 x 145 x 210 mm.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RT1064-2AB36 — Identification
ParameterValue
Contactor frame sizeS10
3RT1064-2AB36 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V195 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1064-2AB36 — Control & Coil
ParameterValue
Control supply voltage typeAC/DC
Rated value @ 50 Hz0.9
Rated value @ 50 Hz23 ... 26 V
3RT1064-2AB36 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1064-2AB36 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 500 A (690 V, 100 kA)
Short-circuit coordination type 2, fusegG: 400 A (690 V, 100 kA), aM: 315 A (690 V, 50 kA), BS88: 400 A (415 V, 50 kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT1064-2AB36 — Connection & Mounting
ParameterValue
Main circuit connectionConnection bar
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, solid or stranded2x (0,25 ... 2,5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Mounting methodscrew fixing
Side-by-side mountingYes
3RT1064-2AB36 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1064-2AB36 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1064-2AB36 — Mechanical
ParameterValue
Width145 mm
Height210 mm
Depth202 mm
3RT1064-2AB36 — Specifications
ParameterValue
At AC40 ... 80 ms

Product details

SIRIUS S10 power contactor — main terminal sizing and duty-cycle limits

The 3RT1064-2AB36: Switching frequency varies by duty class: up to 750 operations per hour in AC-1 (resistive), 500/h in AC-3 (motor start/run), and 130/h in AC-4 (plugging/inching). The AC-3e rating also caps at 500/h. These are the maximum mechanical limits — actual thermal capacity depends on the load current and ambient temperature.

Panel fit and mounting flexibility

Dimensions are 202 mm deep, 145 mm wide, and 210 mm high. Mounting is by screw fixing through 11 mm diameter holes.

Auxiliary contact ratings and coil data

The contactor includes an auxiliary switch. The coil operates on a rated value of 23-26 V with an initial inrush factor of 0.8 and a full-scale factor of 1.1. Arcing time is 10-15 ms. Operating times (closing/opening) are 40-80 ms for both AC and DC supplies.

Frequently asked questions

What is the main terminal wire range on 3RT1064-2AB36?

The main power terminals accept stranded conductors from 70 mm² up to 240 mm².

How do I get pricing and availability for 3RT1064-2AB36?

Submit an RFQ through the storefront.