Skip to main content
Siemens 3RT1064-2XJ46-0LA2 — Contactors

Siemens 3RT1064-2XJ46-0LA2 SIRIUS Power Contactor, S10, 72 V

MPN3RT1064-2XJ46-0LA2
Active

Siemens SIRIUS S10 power contactor, 3RT1064-2XJ46-0LA2, 72 VDC coil, screw fixing, 202 mm depth, auxiliary switch included.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1064-2XJ46-0LA2 — Identification
ParameterValue
Contactor frame sizeS10
3RT1064-2XJ46-0LA2 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V195 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V82 kW
Rated value @ 230 V6 A
Rated value @ 24 V6 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1064-2XJ46-0LA2 — Control & Coil
ParameterValue
Control supply voltage typeDC
3RT1064-2XJ46-0LA2 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
3RT1064-2XJ46-0LA2 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 500 A (690 V, 100 kA)
Short-circuit coordination type 2, fusegG: 400 A (690 V, 100 kA), aM: 315 A (690 V, 50 kA), BS88: 400 A (415 V, 50 kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT1064-2XJ46-0LA2 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, solid or stranded2x (0,25 ... 2,5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Mounting methodscrew fixing
Side-by-side mountingYes
3RT1064-2XJ46-0LA2 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1064-2XJ46-0LA2 — Environmental
ParameterValue
Operating temperature range-40 ... +70 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1064-2XJ46-0LA2 — Mechanical
ParameterValue
Width145 mm
Height210 mm
Depth202 mm

Product details

Siemens 3RT1064-2XJ46-0LA2 SIRIUS S10 Power Contactor — 72 VDC Coil, Screw Fixing

The Siemens 3RT1064-2XJ46-0LA2 is a SIRIUS-brand S10 power contactor, 72 VDC coil voltage, designed for heavy switching duty in control panels. Screw fixing mounts it directly to the panel backplate or a mounting rail, with dimensions 202 mm depth, 145 mm width, 210 mm height — factors that dictate cabinet layout and gland-plate clearance. This contactor includes an auxiliary switch and is rated for DC coil control, which means it drops out predictably on DC circuits without the AC hum or dropout delay.

The 72 VDC coil is the critical spec for fit — verify your control voltage matches, as DC coils are polarity-sensitive and have a different pull-in characteristic than AC. The contactor's mechanical life is typical at 10,000,000 operations, but the electrical endurance depends on the load category: at AC-3 (motor starting) it can cycle 500 times per hour, at AC-4 (inching/jogging) only 130 times per hour. For DC loads, DC-1 rates 350 operations per hour, while DC-3 and DC-5 both rate 250. These cycle rates directly affect whether this contactor can handle your application's duty cycle without overheating. Auxiliary contact ratings are given at specific DC voltages: 6 A at 24 VDC, 2 A at 48 V, 2 A at 60 V, 1 A at 110 V, 0.9 A at 125 V. Use these values when sizing control relays or PLC inputs downstream — the 24 V rating is generous, but at 125 V the current drops to 0.9 A, so don't assume the full 6 A holds at higher voltages.

Mounting and Clearance Requirements

These clearances are for arc flash and cooling — in a tight cabinet, forward clearance of 20 mm is the tightest dimension to plan for. Screw fixing uses one hole, 11 mm diameter. This is standard for control wiring up to 14 AWG; for larger power cables, check the contactor's main terminal specs separately.

Frequently asked questions

How do I get current pricing and availability for 3RT1064-2XJ46-0LA2?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit a request for quote (RFQ) to confirm current pricing and lead time.

What are the key dimensions for panel layout?

The contactor has a depth of 202 mm, width 145 mm, and height 210 mm. Minimum clearances required are 10 mm upward, 20 mm forward, 10 mm downward, and 10 mm at the side.

What conductor sizes does the terminal accept?

The terminals accept solid or stranded conductors from 0.25 to 2.5 mm², with two conductors per terminal allowed.

What is the coil voltage and type?

The coil is DC, rated at 72 V. The contactor includes an auxiliary switch.

MPN
3RT1064-2XJ46-0LA2