Skip to main content
Siemens 3RT1064-6NF36 — Contactors

Siemens 3RT1064-6NF36 SIRIUS S10 Power Contactor, 96-127V Co

MPN3RT1064-6NF36
Active

Siemens SIRIUS S10 power contactor, 3RT1064-6NF36, 96-127 VAC/DC coil, screw-type terminals, 70-240 mm² power circuit, screw fixing.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RT1064-6NF36 — Identification
ParameterValue
Contactor frame sizeS10
3RT1064-6NF36 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V195 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1064-6NF36 — Control & Coil
ParameterValue
Control supply voltage typeAC/DC
Rated value @ 50 Hz0.4
Rated value @ 50 Hz96 ... 127 V
3RT1064-6NF36 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1064-6NF36 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 500 A (690 V, 100 kA)
Short-circuit coordination type 2, fusegG: 400 A (690 V, 100 kA), aM: 315 A (690 V, 50 kA), BS88: 400 A (415 V, 50 kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT1064-6NF36 — Connection & Mounting
ParameterValue
Main circuit connectionConnection bar
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew fixing
Side-by-side mountingYes
3RT1064-6NF36 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1064-6NF36 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1064-6NF36 — Mechanical
ParameterValue
Width145 mm
Height210 mm
Depth202 mm
3RT1064-6NF36 — Specifications
ParameterValue
At AC80 ... 100 ms

Product details

The 3RT1064-6NF36: The power circuit accepts stranded cable from 70 to 240 mm² — that's a serious lug range, sized for motor feeders up to roughly 200-300 A depending on duty cycle and ambient. The coil termination uses screw-type terminals, so you're not fighting cage clamps on the control wiring; a #8 or #10 ring terminal lands cleanly. The mounting position allows vertical surface mounting with ±90° rotation and ±22.5° tilt front-to-back, so you can orient it to fit tight gland-plate layouts — just keep the arc chamber clearances in mind (10 mm sideways, 10 mm up/down, 20 mm forward). Mechanical life is rated at 10,000,000 typical operations — that's a decade-plus on a cycling conveyor or pump start, and the switching rates (500 ops/h at AC-3, 750 ops/h at AC-1) confirm it's built for continuous process duty, not just infrequent isolation.

SIRIUS S10 contactors are the standard building block for motor control centers and distribution panels in manufacturing, water/wastewater, HVAC, and material handling. This size handles the heavy feeders — think 100+ kW motors, large pumps, or compressor trains — where the power wiring needs the 240 mm² lug capacity and the panel builder needs the screw-fixing reliability.

Frequently asked questions

What coil voltage does this contactor use?

The coil is rated 96-127 VAC/DC with pickup at 0.8x rated value, so it reliably pulls in at about 77 V and holds across the full range.

What size cable does the power circuit accept?

The power terminals accept stranded cable from 70 mm² up to 240 mm² — suitable for heavy motor feeders.

What are the mounting dimensions and clearances?

The contactor measures 210 mm high, 202 mm deep, 145 mm wide. It requires screw fixing, vertical mounting surface with ±90° rotation, and minimum clearances of 10 mm sideways, 10 mm up/down, and 20 mm forward for arc chamber venting.

MPN
3RT1064-6NF36