Siemens 3RT1065-6AP36 — Contactors

Siemens 3RT1065-6AP36 SIRIUS S10 Power Contactor, 220-240 VA

MPN3RT1065-6AP36
Active

Siemens SIRIUS S10, power contactor, 3RT1065-6AP36, 220-240 VAC coil, screw-type terminals, size S10.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RT1065-6AP36 — Identification
ParameterValue
Contactor frame sizeS10
3RT1065-6AP36 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V230 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1065-6AP36 — Control & Coil
ParameterValue
Control supply voltage typeAC/DC
Rated value @ 50 Hz0.9
Rated value @ 50 Hz220 ... 240 V
3RT1065-6AP36 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1065-6AP36 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 500 A (690 V, 100 kA)
Short-circuit coordination type 2, fusegG: 400 A (690 V, 100 kA), aM: 315 A (690 V, 50 kA), BS88: 400 A (415 V, 50 kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT1065-6AP36 — Connection & Mounting
ParameterValue
Main circuit connectionConnection bar
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew fixing
Side-by-side mountingYes
3RT1065-6AP36 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1065-6AP36 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1065-6AP36 — Mechanical
ParameterValue
Width145 mm
Height210 mm
Depth202 mm
3RT1065-6AP36 — Specifications
ParameterValue
At AC40 ... 80 ms

Product details

SIRIUS S10 power contactor — 220-240 VAC coil, size S10

Size S10 frames this for motor loads in the 55-75 kW range typical of conveyor, pump, and compressor duty. The coil holds at 0.8 of rated value and full-scale pick-up is 1.1 — so on a 230 V line it pulls in reliably down to about 184 V and drops out below that margin.

Main pole cable cross-section accepts stranded conductors up to 240 mm² — that's the terminal capacity for the power circuit, not a current rating, but it tells you the contactor is sized for heavy feeds. Auxiliary contacts switch 10 A at 24 V rated value, 2 A at 48 V and 60 V, and 1 A at 110 V — enough for PLC or relay interface circuits on the control side. Maximum switching frequency varies by duty: 800 cycles/hour in AC-1 (resistive), 500 in AC-3 (motor start/run), 250 in AC-2 (slip-ring motor), and 130 in AC-4 (plugging/inching). The AC-3e rating also sits at 500 cycles/hour. For a conveyor line running continuous start/stop, that 500 cycles/hour ceiling governs the real throughput — not the resistive number. Arcing time sits at 10-15 ms, with opening times of 40-80 ms on both AC and DC coils. That timing matters for coordination with upstream short-circuit protection — a downstream fault needs to clear before the contactor's arc extinguishes.

The single 11 mm hole for screw fixing is standard for S10 frame. Dimensions are 210 mm height, 145 mm width, 202 mm depth — plan the DIN-rail or backplate layout accordingly.

Frequently asked questions

Where can I buy 3RT1065-6AP36 and how is it quoted for volume?

The 3RT1065-6AP36 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock count or price is published here.

What is 3RT1065-6AP36's coil voltage and what does pick-up/drop-out mean?

The coil is rated 220-240 VAC. Pick-up (full-scale value) is 1.1, meaning it pulls in reliably at about 253 V on a 230 V line; initial value is 0.8, so it holds closed down to about 184 V before dropping out.

What cable cross-section does 3RT1065-6AP36 accept on the main poles?

The main poles accept stranded conductors up to 240 mm². Auxiliary and coil terminals accept 2x (0.5-1.5 mm²) solid, 2x (0.75-2.5 mm²) solid or stranded, and up to 2x (0.75-4 mm²) maximum.