Siemens 3RT1066-2AB36 — Contactors

Siemens 3RT1066-2AB36 SIRIUS Power Contactor, S10, 23-26 VDC

MPN3RT1066-2AB36
Active

Siemens SIRIUS power contactor, S10 frame, 23-26 VDC coil, spring-type terminals, screw fixing, 202 x 145 x 210 mm.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RT1066-2AB36 — Identification
ParameterValue
Contactor frame sizeS10
3RT1066-2AB36 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V280 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1066-2AB36 — Control & Coil
ParameterValue
Control supply voltage typeAC/DC
Rated value @ 50 Hz0.9
Rated value @ 50 Hz23 ... 26 V
3RT1066-2AB36 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1066-2AB36 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 500 A (690 V, 100 kA)
Short-circuit coordination type 2, fusegG: 400 A (690 V, 100 kA), aM: 315 A (690 V, 50 kA), BS88: 400 A (415 V, 50 kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT1066-2AB36 — Connection & Mounting
ParameterValue
Main circuit connectionConnection bar
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, solid or stranded2x (0,25 ... 2,5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Mounting methodscrew fixing
Side-by-side mountingYes
3RT1066-2AB36 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1066-2AB36 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1066-2AB36 — Mechanical
ParameterValue
Width145 mm
Height210 mm
Depth202 mm
3RT1066-2AB36 — Specifications
ParameterValue
At AC40 ... 80 ms

Product details

SIRIUS S10 Power Contactor, 23-26 VDC Coil

The coil is rated for a 23-26 VDC pickup range, with a 1.1x full-scale value and an initial pickup threshold of 0.8x rated voltage — per the datasheet, that means it pulls in reliably at about 18.4 VDC and holds across the nominal band. Mounting is via screw fixing with four 11 mm holes on a vertical surface, rotatable ±90° and tiltable ±22.5° front-to-back. The main power terminals accept stranded cable from 70 to 240 mm²; the coil connection uses spring-type terminals accepting 2x (0.25 to 2.5 mm²) solid or stranded. That spring cage on the coil side saves panel-builder time — no screw torque to verify, just strip to 8 mm and insert. Dimensions are 202 mm deep, 145 mm wide, 210 mm tall.

The contactor carries an auxiliary switch rated at 10 A at 24 V, 2 A at 48 V, 2 A at 60 V, and 1 A at 110 V. The main contact switching frequency varies by duty class: 750 operations per hour maximum at AC-1 (resistive), 250/h at AC-2 (slip-ring motors), 500/h at AC-3 (squirrel-cage motors), and 130/h at AC-4 (plugging/inching). The AC-3e rating matches the AC-3 figure at 500/h. The power factor at 50 Hz and 60 Hz is 0.9. The mechanical life of the contactor is typically 10,000,000 operations.

Frequently asked questions

What is the coil voltage range for the 3RT1066-2AB36?

The coil is rated for 23-26 VDC, with a pickup threshold of 0.8x rated (approximately 18.4 VDC) and a 1.1x full-scale value.

Where can I buy the 3RT1066-2AB36?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
3RT1066-2AB36