Siemens 3RT1066-6AP36-ZX95 — Contactors

Siemens 3RT1066-6AP36-ZX95 SIRIUS Power Contactor, S10

MPN3RT1066-6AP36-ZX95
Active

Siemens SIRIUS power contactor, size S10, 220-240 V AC 50/60 Hz coil, screw-type coil terminals, 3-pole, main current path accepting 70-240 mm² stranded copper.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RT1066-6AP36-ZX95 — Identification
ParameterValue
Contactor frame sizeS10
3RT1066-6AP36-ZX95 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V280 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1066-6AP36-ZX95 — Control & Coil
ParameterValue
Control supply voltage typeAC/DC
Rated value @ 50 Hz0.9
Rated value @ 50 Hz220 ... 240 V
3RT1066-6AP36-ZX95 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1066-6AP36-ZX95 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 500 A (690 V, 100 kA)
Short-circuit coordination type 2, fusegG: 400 A (690 V, 100 kA), aM: 315 A (690 V, 50 kA), BS88: 400 A (415 V, 50 kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT1066-6AP36-ZX95 — Connection & Mounting
ParameterValue
Main circuit connectionConnection bar
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew fixing
Side-by-side mountingYes
3RT1066-6AP36-ZX95 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1066-6AP36-ZX95 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1066-6AP36-ZX95 — Mechanical
ParameterValue
Width145 mm
Height210 mm
Depth202 mm
3RT1066-6AP36-ZX95 — Specifications
ParameterValue
At AC40 ... 80 ms

Product details

The 3RT1066-6AP36-ZX95: The 220-240 V AC coil (50/60 Hz) draws its magnetising current from the control transformer; the screw-type coil terminals accept up to 4 mm² stranded or solid wire. The main power path accepts stranded copper from 70 mm² up to 240 mm² — that is a serious conductor cross-section, sized for high-current feeders typical of large motor starters or distribution. The contactor is fastened by screw fixing through an 11 mm hole, not DIN-rail snap-on, so plan the backplate layout accordingly. That helps in tight enclosures where the contactor must sit at an angle to clear busbars or other gear. The wide storage band is typical for SIRIUS gear — it ships fine in unheated warehouses.

Switching frequency and duty-cycle limits

The maximum switching rate depends on the utilisation category: 750 operations/hour in AC-1 (resistive), 500/h in AC-3 (squirrel-cage motor start/run), 250/h in AC-2 (slip-ring motor), and 130/h in AC-4 (plugging/inching). The AC-3e rating also sits at 500/h. These are the contactor's thermal limits — exceeding them shortens life or welds the main poles. Arcing time is 10-15 ms, and the opening/closing times (including bounce) are 40-80 ms for both AC and DC operation. That matters for coordination with upstream short-circuit protection — the total clearing time of the fuse or MCCB must account for the contactor's arcing window. The contactor includes an auxiliary switch block (1 NO + 1 NC typical for S10), which can be wired for feedback to the PLC or for electrical interlocking.

Clearance and wiring space

Physical envelope: 210 mm high, 145 mm wide, 202 mm deep. That is a large contactor — the S10 frame is the biggest in the SIRIUS line, so verify the enclosure depth before committing. The forward clearance is the tightest — 20 mm is barely enough for the main cable lugs and the arc chute. The main power terminals accept 70-240 mm² stranded copper — that is a single large cable per pole or parallel smaller cables. The auxiliary terminals accept 0.5-1.5 mm² solid or 0.75-2.5 mm² stranded, up to 4 mm² maximum. Use ferrules on stranded wire for reliable termination in the screw cages.

Sourced to order against the BOM quantity.

Frequently asked questions

What size main conductors does this contactor accept?

The main power terminals accept stranded copper from 70 mm² up to 240 mm² per pole.

MPN
3RT1066-6AP36-ZX95