Skip to main content
Siemens 3RT1076-2AP36 — Contactors

3RT1076-2AP36 - Siemens

MPN3RT1076-2AP36
Active

power contactor, AC-3e/AC-3 500 A, 250 kW / 400 V AC (50-60 Hz) / DC Uc: 220-240 V 3-pole, auxiliary contacts 2 NO + 2 NC drive: conventional main circuit: busbar control and auxiliary circuit: spring-loaded terminal

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1076-2AP36 — Identification
ParameterValue
Contactor frame sizeS12
3RT1076-2AP36 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V430 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1076-2AP36 — Control & Coil
ParameterValue
Control supply voltage typeAC/DC
Rated value @ 50 Hz0.9
Rated value @ 50 Hz220 ... 240 V
3RT1076-2AP36 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1076-2AP36 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 630 A (690 V, 100 kA)
Short-circuit coordination type 2, fusegG: 500 A (690 V, 100 kA), aM: 500 A (690 V, 50 kA), BS88: 500 A (415 V, 50 kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT1076-2AP36 — Connection & Mounting
ParameterValue
Main circuit connectionConnection bar
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, solid or stranded2x (0,25 ... 2,5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Mounting methodscrew fixing
Side-by-side mountingYes
3RT1076-2AP36 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1076-2AP36 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1076-2AP36 — Mechanical
ParameterValue
Width160 mm
Height214 mm
Depth225 mm
3RT1076-2AP36 — Specifications
ParameterValue
At AC60 ... 100 ms

Frequently asked questions

What is the coil voltage of the Siemens 3RT1076-2AP36?

Coil voltage mismatch is the most common return reason for 500 A contactors and blocks panel commissioning.

Where can I buy 3RT1076-2AP36 with traceability and a certificate of conformance?

500 A Siemens contactors carry heavy counterfeit risk through brokers; proof of traceability directly affects buy decisions.

What is the difference between 3RT1076-2AP36 and 3RT1076-2AP66?

AP suffix variants differ in terminal type and dimensions, causing ordering errors that delay panel builds.

How many auxiliary contacts does the 3RT1076-2AP36 have and what is their rating?

2 NO + 2 NC aux contacts drive interlock and feedback logic; AC vs DC rating split trips up panel wiring if not clarified.

Is 3RT1076-2AP36 suitable as a line or bypass contactor for a 250 kW VFD?

VFD bypass and line contactor selection depends on AC-3e rating, switching life, and busbar termination clearance.

What is the short-circuit withstand and Type-2 coordination data for 3RT1076-2AP36?

Discrimination studies require fused coordination values that are scattered across Sirius manuals and breaker guides.

MPN
3RT1076-2AP36