Siemens 3RT1076-6XB46-0LA2 — Contactors

Siemens 3RT1076-6XB46-0LA2 SIRIUS Contactor, 24 VDC Coil

MPN3RT1076-6XB46-0LA2
Active

Siemens SIRIUS 3RT1076-6XB46-0LA2 contactor, size S12, 24 VDC coil, screw fixing, auxiliary switch, 225 mm depth, 160 mm width, 214 mm height.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RT1076-6XB46-0LA2 — Identification
ParameterValue
Contactor frame sizeS12
3RT1076-6XB46-0LA2 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V430 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V148 kW
Rated value @ 230 V6 A
Rated value @ 24 V6 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1076-6XB46-0LA2 — Control & Coil
ParameterValue
Control supply voltage typeDC
3RT1076-6XB46-0LA2 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
3RT1076-6XB46-0LA2 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 630 A (690 V, 100 kA)
Short-circuit coordination type 2, fusegG: 500 A (690 V, 100 kA), aM: 500 A (690 V, 50 kA), BS88: 500 A (415 V, 50 kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT1076-6XB46-0LA2 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew fixing
Side-by-side mountingYes
3RT1076-6XB46-0LA2 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1076-6XB46-0LA2 — Environmental
ParameterValue
Operating temperature range-40 ... +70 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1076-6XB46-0LA2 — Mechanical
ParameterValue
Width160 mm
Height214 mm
Depth225 mm

Product details

Sizing the coil and auxiliary contacts for the control circuit

The 3RT1076-6XB46-0LA2: The coil operating range spans 0.7 to 1.25 times the rated value — at 24 VDC nominal, pickup is guaranteed at 16.8 V and the coil must not see sustained overvoltage above 30 V. These are the DC-13 breaking limits — the same auxiliary contact used on a 24 VDC PLC output will handle the solenoid load without welding.

Switching frequency and duty-cycle limits

Maximum switching rates are duty-dependent: 500 operations per hour in AC-1 (resistive), 420 ops/h in AC-3 (motor starting), 170 ops/h in AC-2 (slip-ring motor), and 130 ops/h in AC-4 (plugging/inching). For DC loads, the ceiling is 250 ops/h in DC-1 and 200 ops/h in DC-3 or DC-5.

Physical fit and mounting constraints

The contactor measures 225 mm deep, 160 mm wide, and 214 mm high. It mounts via screw fixing through two 11 mm diameter holes — no DIN-rail adapter on this variant, so plan for a backplate or sub-panel with clearance for the M10 or 3/8-inch bolts.

Frequently asked questions

What are the key ratings for 3RT1076-6XB46-0LA2?

The contactor has a 24 VDC coil, size S12 frame, with an auxiliary switch rated 6 A at 24 VDC. Maximum switching frequency in AC-3 duty is 420 operations per hour. Dimensions are 225 mm depth, 160 mm width, 214 mm height.

How can I order 3RT1076-6XB46-0LA2?

No stock-holding claim is made — submit a quote request for your volume and lead-time needs.

MPN
3RT1076-6XB46-0LA2