Skip to main content
Siemens 3RT1264-6AM36 — Contactors

Siemens 3RT1264-6AM36 SIRIUS Vacuum Contactor, S10, 200-220V

MPN3RT1264-6AM36
Active

Siemens SIRIUS vacuum contactor, size S10, order code 3RT1264-6AM36, 200-220 V AC coil, screw-type terminals, 210 x 145 x 206 mm.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1264-6AM36 — Identification
ParameterValue
Contactor frame sizeS10
3RT1264-6AM36 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V195 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1264-6AM36 — Control & Coil
ParameterValue
Control supply voltage typeAC/DC
Rated value @ 50 Hz0.9
Rated value @ 50 Hz200 ... 220 V
3RT1264-6AM36 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1264-6AM36 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 500 A (690 V, 100 kA)
Short-circuit coordination type 2, fusegG: 500 A (690 V, 100 kA), aM: 400 A (690 V, 50 kA), BS88: 450 A (415 V, 50 kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT1264-6AM36 — Connection & Mounting
ParameterValue
Main circuit connectionConnection bar
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew fixing
Side-by-side mountingYes
3RT1264-6AM36 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1264-6AM36 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1264-6AM36 — Mechanical
ParameterValue
Width145 mm
Height210 mm
Depth206 mm
3RT1264-6AM36 — Specifications
ParameterValue
At AC40 ... 80 ms

Product details

Siemens 3RT1264-6AM36 — SIRIUS S10 Vacuum Contactor

Vacuum contactors are preferred for high-cycle, high-voltage applications because the sealed vacuum chamber extinguishes the arc without exposing contacts to air, giving longer electrical life than open-air contactors at equivalent ratings. The coil is rated at 200-220 V AC, with screw-type terminals for the magnet coil and a main circuit that accepts stranded conductors from 70 to 240 mm². Auxiliary switch is included on the contactor. Mechanical life is typical 10,000,000 operations. Switching frequency depends on duty class: up to 800 ops/h in AC-1 (resistive), 750 ops/h in AC-3 (squirrel-cage motor starting), and 250 ops/h in AC-4 (plugging/inching).

Fastening is screw fixing through a single 11 mm diameter hole. The contactor can be mounted on a vertical surface with ±22.5° rotation, or tilted forward/backward by the same angle; it can also stand on a horizontal mounting surface. Dimensions are 210 mm height, 145 mm width, 206 mm depth. The S10 frame size is one of the larger SIRIUS contactor footprints, sized for the 70-240 mm² cable range. The mounting position flexibility allows panel layout optimization in tight enclosures.

Terminal & Wiring

Auxiliary conductor connections accept solid or stranded wires: 2x (0.5-1.5 mm²), 2x (0.75-2.5 mm²), or max 2x (0.75-4 mm²). Main circuit stranded cable range is 70-240 mm². The contactor also carries an auxiliary switch as standard.

Switching Performance

Arcing time is 10-15 ms. Switching times at AC and DC are both 40-80 ms. The power factor at 50 Hz and 60 Hz is 0.9. Pick-up voltage initial value is 0.8 of rated, with full-scale value 1.1.

Frequently asked questions

Where can I buy 3RT1264-6AM36 and how do I get a price?

This contactor is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and delivery estimate.

What is the closest functional second-source for 3RT1264-6AM36?

The peer 3RT1264-6AP36-0KA1 is a functional second-source candidate — same S10 frame, same SIRIUS vacuum contactor family. The key difference is the coil voltage variant; verify the 3RT1264-6AP36-0KA1 coil rating matches your control voltage before substituting. Mechanical fit and terminal layout are identical.

What is 3RT1264-6AM36's listed depth?

The depth is 206 mm. Overall dimensions are 210 mm height x 145 mm width x 206 mm depth.

Will 3RT1264-6AM36 drop into a panel specified around 3RT1264-6AP36-0KA1 without rewiring?

Yes, the mechanical footprint and terminal layout are identical within the S10 frame. The mounting hole pattern (single 11 mm hole) and clearance requirements (10 mm up/down/side, 20 mm forward) are the same. The only difference is the coil voltage — verify that the 3RT1264-6AM36's 200-220 V AC coil matches your control circuit.

What compliance documentation does Siemens provide for 3RT1264-6AM36?

As a current-production Siemens SIRIUS component, this contactor carries CE marking for the European market and is designed to meet relevant IEC/EN standards for contactors (IEC 60947-4-1). RoHS and REACH compliance declarations are available from Siemens upon request. Specific UL/CSA listings should be verified against the nameplate marking on the unit.

MPN
3RT1264-6AM36