Siemens 3RT1265-6AR36 — Contactors

Siemens 3RT1265-6AR36 SIRIUS Vacuum Contactor, S10 Size, 440

MPN3RT1265-6AR36
Active

Siemens SIRIUS vacuum contactor, size S10, order code 3RT1265-6AR36, rated 440-480 V, screw fixing, 206 mm depth.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1265-6AR36 — Identification
ParameterValue
Contactor frame sizeS10
3RT1265-6AR36 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V230 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1265-6AR36 — Control & Coil
ParameterValue
Control supply voltage typeAC/DC
Rated value @ 50 Hz0.9
Rated value @ 50 Hz440 ... 480 V
3RT1265-6AR36 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1265-6AR36 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 500 A (690 V, 100 kA)
Short-circuit coordination type 2, fusegG: 500 A (690 V, 100 kA), aM: 400 A (690 V, 50 kA), BS88: 450 A (415 V, 50 kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT1265-6AR36 — Connection & Mounting
ParameterValue
Main circuit connectionConnection bar
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew fixing
Side-by-side mountingYes
3RT1265-6AR36 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1265-6AR36 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1265-6AR36 — Mechanical
ParameterValue
Width145 mm
Height210 mm
Depth206 mm
3RT1265-6AR36 — Specifications
ParameterValue
At AC40 ... 80 ms

Product details

What this SIRIUS vacuum contactor is

Vacuum contactors use a sealed vacuum interrupter to extinguish the arc, which means no arc chute maintenance and a clean break even on high-inductance loads. The rated voltage range is 440 to 480 V, so it fits standard 480 V three-phase distribution in North America and 400/440 V systems elsewhere.

The S10 frame size tells you the physical envelope and the current-carrying capacity of the main poles. Main power lugs accept stranded cable from 70 to 240 mm² — that's a heavy lug range, sized for feeders up to several hundred amps depending on duty class. The auxiliary contact block is present (Auxiliary Switch: Yes), so you get a set of N.O./N.C. mirrors for feedback or interlocking without adding a separate side-mount block.

Mounting is by screw fixing — not DIN-rail snap-on — so plan for drilled holes in the backplate or mounting channel. The fastening method uses one hole of 11 mm diameter. That's tighter than some contactors, so check your enclosure layout. Dimensions: 210 mm high, 145 mm wide, 206 mm deep. That depth is the body plus the arc chamber; factor in wiring space behind the panel.

Frequently asked questions

What are the main power lug wire ranges?

Main power lugs accept stranded cable from 70 to 240 mm². That's a heavy-duty range, suitable for feeders up to several hundred amps depending on the duty class.

Does this contactor include auxiliary contacts?

Yes. The auxiliary switch is present, providing built-in N.O./N.C. contacts for feedback or interlocking without an add-on block.

What are the clearance distances needed around this contactor?

Minimum clearances: 10 mm upwards, 10 mm downwards, 20 mm forwards, and 10 mm at the side. These are tighter than some contactors, so verify your enclosure layout.

What is the mechanical life rating?

Mechanical life is listed at 10,000,000 operations typical. This is the mechanical endurance, not the electrical endurance under load, but it indicates suitability for high-cycle applications.

MPN
3RT1265-6AR36