Siemens 3RT1266-6LA06 — Contactors

Siemens 3RT1266-6LA06 SIRIUS Vacuum Contactor, S10

MPN3RT1266-6LA06
Active

Siemens SIRIUS 3RT1266-6LA06 vacuum contactor, S10 frame size, 302 A at 480 V AC-3, 3-pole, screw fixing, 70-240 mm² stranded main conductors.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1266-6LA06 — Identification
ParameterValue
Contactor frame sizeS10
3RT1266-6LA06 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V280 A
Rated value @ 400 V3 A
Rated value @ 500 V200 kW
Rated value @ 690 V1 A
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1266-6LA06 — Control & Coil
ParameterValue
Control supply voltage typeAC/DC
3RT1266-6LA06 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1266-6LA06 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 500 A (690 V, 100 kA)
Short-circuit coordination type 2, fusegG: 500 A (690 V, 100 kA), aM: 400 A (690 V, 50 kA), BS88: 450 A (415 V, 50 kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT1266-6LA06 — Connection & Mounting
ParameterValue
Main circuit connectionConnection bar
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew fixing
Side-by-side mountingYes
3RT1266-6LA06 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1266-6LA06 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1266-6LA06 — Mechanical
ParameterValue
Width145 mm
Height210 mm
Depth206 mm
3RT1266-6LA06 — Specifications
ParameterValue
At AC40 ... 80 ms

Product details

S10 vacuum contactor built for heavy switching

The Siemens 3RT1266-6LA06 is a SIRIUS vacuum contactor in the S10 frame size, designed for motor switching and resistive loads where the arc needs to be extinguished fast and cleanly — the vacuum bottle does that in 10-15 ms arcing time. Rated 302 A at 480 V in AC-3 duty, this contactor handles the full-load current of a 200-250 hp motor at 480 V without derating the main poles.

Power terminations and wiring constraints

Main power conductors land on screw-type terminals that accept stranded cable from 70 mm² up to 240 mm² — that is a 2/0 AWG to 500 kcmil range, sized for the full 302 A without needing parallel runs. The magnet coil has its own screw-type terminals, separate from the main power lugs, so the control wiring stays isolated from the high-current path.

Mounting and panel clearance

Fastening is by screw fixing through a single 11 mm diameter hole — no DIN rail clip on the S10 frame, so budget for a drilled backplate or mounting bracket. The contactor measures 210 mm high, 145 mm wide, and 206 mm deep, including the arc chute and coil housing. Minimum clearances: 10 mm above and below, 10 mm to the sides, and 20 mm forward of the arc chamber — respect these to keep the arc flash from tracking to adjacent gear.

Mechanical endurance is 10 million cycles typical — the vacuum interrupter contacts do not erode the way air-break contacts do, so the rated life is effectively the coil and mechanism wear limit. Maximum switching rates: 750 operations per hour in AC-1 and AC-3 duty, 250 ops/h in AC-2 and AC-4 — the heavier the load make/break, the more thermal recovery time the contactor needs between operations.

Temperature range and auxiliary contact ratings

An auxiliary switch block is built in.

MPN
3RT1266-6LA06