Skip to main content
Siemens 3RT1266-6NP36

Siemens 3RT1266-6NP36 SIRIUS Vacuum Contactor, Size S10

MPN 3RT1266-6NP36
Active

Siemens SIRIUS 3RT1266-6NP36 vacuum contactor, Size S10, 200-277 V AC/DC magnet coil, screw-type terminals, with auxiliary switch, screw fixing.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RT1266-6NP36 specifications
ParameterValue
Mountingscrew fixing
Depth206 mm
Width145 mm
Height210 mm
Arcing time10 ... 15 ms

Product details

Vacuum contactor for high-cycle motor switching

The Siemens 3RT1266-6NP36 is a SIRIUS vacuum contactor in Size S10, designed for applications where arc extinction and contact life are critical — vacuum bottles quench the arc in a sealed chamber, so the main contacts see minimal erosion even under frequent AC-3 or AC-4 duty.

Mounting and clearance for panel integration

Fastening is by screw fixing through a single 11 mm hole — the contactor is bolted, not DIN-rail snapped, so the panel backplate needs a drilled and tapped location. Dimensions are 210 mm high × 145 mm wide × 206 mm deep — the depth is the dominant constraint for enclosure selection; a standard 300 mm deep cabinet leaves about 94 mm for wiring and arc chute clearance behind the door.

Switching performance and auxiliary contact ratings

Mechanical endurance is 10 million operating cycles typical — the vacuum interrupter contributes to this by eliminating contact erosion from arcing in air, so the contactor outlasts an equivalent air-break unit in high-cycle applications like conveyor or pump cycling. Maximum switching rates: 750 operations per hour in AC-1 and AC-3 duty, 250 ops/h in AC-2 and AC-4 — AC-4 (plugging/inching) is the most severe; the 250 ops/h limit reflects the thermal recovery time of the vacuum bottle after a high-energy break.

Power cable termination and ambient limits

Main power conductors: stranded 70–240 mm² — this is a heavy cable range, consistent with a Size S10 contactor rated for motor currents up to roughly 400–500 A in AC-3; the lug or crimp terminal must match the contactor's bus bar hole pattern. Coil power factor at 50/60 Hz is 0.4 — this is the phase angle between voltage and current in the AC coil circuit; a control transformer feeding multiple such contactors must be sized for the apparent power (VA), not just the real power (W), to avoid saturation on inrush.

MPN
3RT1266-6NP36