Skip to main content
Siemens 3RT1276-6NF36 — Contactors

Siemens 3RT1276-6NF36 SIRIUS Vacuum Contactor, S12

MPN3RT1276-6NF36
Active

Siemens SIRIUS 3RT1276-6NF36 vacuum contactor, size S12, 3-pole, 225 mm depth, 214 mm height, 160 mm width, screw-type coil terminals, 96-127 V AC/DC coil.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1276-6NF36 — Identification
ParameterValue
Contactor frame sizeS12
3RT1276-6NF36 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V430 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1276-6NF36 — Control & Coil
ParameterValue
Control supply voltage typeAC/DC
Rated value @ 50 Hz0.4
Rated value @ 50 Hz96 ... 127 V
3RT1276-6NF36 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1276-6NF36 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 800 A (690 V, 100 kA)
Short-circuit coordination type 2, fusegG: 800 A (690 V, 50 kA), aM: 630 A (690 V, 50 kA), BS88: 800 A (415 V, 50 kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT1276-6NF36 — Connection & Mounting
ParameterValue
Main circuit connectionConnection bar
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew fixing
Side-by-side mountingYes
3RT1276-6NF36 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1276-6NF36 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1276-6NF36 — Mechanical
ParameterValue
Width160 mm
Height214 mm
Depth225 mm
3RT1276-6NF36 — Specifications
ParameterValue
At AC80 ... 100 ms

Product details

The 3RT1276-6NF36: This is a Siemens SIRIUS vacuum contactor in the S12 frame size — the vacuum bottle extinguishes the arc inside a sealed chamber, so the contact gap stays clean and the switching life holds up under high-cycle motor starting or furnace duty where an air-break contactor would pit the contacts after a few thousand operations. The physical envelope is 225 mm deep by 214 mm high by 160 mm wide — the depth is the dimension that usually bites you on a shallow backpanel or a retrofit into an existing enclosure where the gland plate or busbar trunking limits how far the contactor projects from the mounting surface. Coil voltage is 96 to 127 V AC/DC with screw-type terminals — the wide AC/DC tolerance means it holds in on a control transformer with a sagging secondary or a battery-backed DC bus, provided the initial pickup voltage stays above 0.8 × rated value and the full-scale overvoltage does not exceed 1.1 × rated. Main power cables land on terminals accepting 70 to 240 mm² stranded copper — that is a 4/0 AWG to 500 kcmil range, sized for the full rated current of the contactor without needing a separate lug adapter on the line or load side.

Switching frequency and duty-cycle limits

The contactor is rated for 750 operations per hour in AC-3 and AC-3e duty (squirrel-cage motor starting) and 700 ops/h in AC-1 (resistive load) — the vacuum bottle handles the arc without the thermal recovery delay that limits an air-break contactor, so the cycle rate is set by the magnet system heating, not the main contacts. In AC-2 (slip-ring motor starting) and AC-4 (plugging / inching) the rate drops to 250 ops/h — the longer arcing time during reversal heats the vacuum bottle envelope, and the manufacturer's rating assumes the contactor is not operated above this frequency without a duty-cycle derating.

Frequently asked questions

What coil voltage does the 3RT1276-6NF36 require?

The coil is rated for 96 to 127 V AC/DC with screw-type terminals — it operates on both AC and DC control supplies within that range.

What is the maximum switching frequency in AC-3 duty?

The contactor is rated for 750 operations per hour in AC-3 and AC-3e duty — the vacuum bottle allows this high cycle rate without contact maintenance.

MPN
3RT1276-6NF36