Skip to main content
Siemens 3RT1316-2AK60 — Contactors

Siemens 3RT1316-2AK60 SIRIUS Power Contactor, 4 NO, 4 kW AC-

MPN3RT1316-2AK60

Siemens SIRIUS power contactor, Size S00, 4 NO main contacts, spring-loaded terminals, 4 kW at 400 V AC-2, 45 mm width, active production.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1316-2AK60 — Identification
ParameterValue
Contactor frame sizeS00
3RT1316-2AK60 — Ratings & Performance
ParameterValue
Rated value @ 400 V3 A
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1316-2AK60 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.85 ... 1.1
Rated value @ 50 Hz110 V
3RT1316-2AK60 — Contacts & Poles
ParameterValue
Main poles4
Main NO contacts4
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1316-2AK60 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 35 A
Short-circuit coordination type 2, fusefuse gL/gG: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1316-2AK60 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Side-by-side mountingYes
3RT1316-2AK60 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1316-2AK60 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1316-2AK60 — Mechanical
ParameterValue
Width45 mm
Height60 mm
Depth72 mm

Product details

SIRIUS 3RT1316-2AK60 — 4 NO Power Contactor, Size S00

It is rated for 4 kW at 400 V in AC-2 duty (slip-ring motor switching) and handles up to 10 A in AC-12 resistive loads.

The 4 NO configuration means this contactor switches four separate power circuits simultaneously; there are no NC auxiliary contacts built in, so if you need a feedback signal to a PLC, you'll add a separate auxiliary contact block on the side. Spring-loaded terminals accept 2x (0.25 to 2.5 mm²) solid or stranded wire, or 2x (24 to 14 AWG). That's a standard control-panel range — fine for motor leads up to 4 kW. Pollution degree 3 (conductive pollution) is assumed, so the contactor is suited for industrial enclosures where some dust and condensation are present.

Frequently asked questions

What is the depth of 3RT1316-2AK60?

The depth is 72 mm, which fits standard 200 mm deep enclosures with room for wiring.

What wire size does the spring terminal accept?

The spring-loaded terminals accept 2x (0.25 to 2.5 mm²) solid or stranded, or 2x (24 to 14 AWG).

Will 3RT1316-2AK60 drop into a panel specified for 3RT1016-2AP02?

Both are Size S00 contactors on the same 45 mm DIN-rail footprint, so the mechanical fit is the same. The 3RT1316-2AK60 has 4 NO main contacts and spring terminals; the 3RT1016-2AP02 has a different contact configuration and screw terminals. Check your wiring diagram for contact count and terminal type before swapping.

Where can I buy 3RT1316-2AK60?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment.

MPN
3RT1316-2AK60