Skip to main content
Siemens 3RT1316-2AN60 — Contactors

Siemens SIRIUS 3RT1316-2AN60 Power Contactor, 4 NO, S00, 4 k

MPN3RT1316-2AN60

Siemens SIRIUS 3RT1316-2AN60 power contactor, size S00, 4 NO main contacts, 4 kW at 400 V AC-2, spring-loaded terminals, screw and snap-on mounting.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1316-2AN60 — Identification
ParameterValue
Contactor frame sizeS00
3RT1316-2AN60 — Ratings & Performance
ParameterValue
Rated value @ 400 V3 A
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1316-2AN60 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.85 ... 1.1
Rated value @ 50 Hz200 V
3RT1316-2AN60 — Contacts & Poles
ParameterValue
Main poles4
Main NO contacts4
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1316-2AN60 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 35 A
Short-circuit coordination type 2, fusefuse gL/gG: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1316-2AN60 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Side-by-side mountingYes
3RT1316-2AN60 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1316-2AN60 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1316-2AN60 — Mechanical
ParameterValue
Width45 mm
Height60 mm
Depth72 mm

Product details

What this contactor is and what it does

The Siemens SIRIUS 3RT1316-2AN60 is a power contactor in the S00 frame size, designed for switching motor loads and resistive loads in control panels. Its four normally open (NO) main contacts are rated for 4 kW at 400 V in AC-2 duty, which covers slip-ring motor starting and plugging applications. The spring-loaded terminals accept 2x (0.25... 2.5 mm²) solid or stranded conductors, per the datasheet.

Mounting and integration

Mounts via screw or snap-on onto a 35 mm standard mounting rail per DIN EN 50022. The 45 mm width and 72 mm depth fit standard DIN-rail enclosures; side-by-side mounting is permitted without derating for the thermal conditions listed. Pollution degree 3 means it tolerates conductive pollution typical of industrial control cabinets.

Lifecycle and sourcing posture

This part carries a current production lifecycle status. For a BOM line or a replacement order, the 3RT1316-2AN60 is sourced to order against an RFQ. No official successor has been issued; the S00 frame and 4 NO configuration are current catalog items.

Key ratings and what they mean for fit

The 4 kW rating at 400 V AC-2 is the motor-switching capability under moderate overload conditions — relevant for slip-ring motors or applications requiring frequent reversing. The operating temperature range of -25 to +60 °C during operation covers most indoor industrial environments without forced cooling. The 10 A rated operational current at AC-12 (resistive load) at 24 V gives a reference for control-circuit switching.

Frequently asked questions

What are the main contact ratings for this contactor?

Four normally open (NO) main contacts. Motor rating is 4 kW at 400 V AC-2. Resistive (AC-12) rating is 10 A at 24 V. Other switching capacities include 6 A at 230 V and 3 A at 400 V.

What terminal type does this contactor use?

Spring-loaded terminals for the main current circuit, accepting 2x (0.25... 2.5 mm²) solid or stranded conductors, or 2x (24... 14) AWG.

What is the physical size of the 3RT1316-2AN60?

Width 45 mm, height 60 mm, depth 72 mm. Frame size S00. Mounts on 35 mm DIN rail per DIN EN 50022.

What is the closest functional alternative to this contactor?

The 3RT1016-2AP02 is a peer in the same S00 frame but with screw terminals instead of spring-loaded terminals. The 3RT1016-1AN22 also uses spring-loaded terminals but has a different coil voltage. Verify coil voltage and terminal type before substituting.

MPN
3RT1316-2AN60