Specifications

3RT1316-2AP00 — Identification
ParameterValue
Contactor frame sizeS00
3RT1316-2AP00 — Ratings & Performance
ParameterValue
Rated value @ 400 V4 kW
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1316-2AP00 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz230 V
3RT1316-2AP00 — Contacts & Poles
ParameterValue
Main poles4
Main NO contacts4
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1316-2AP00 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 35 A
Short-circuit coordination type 2, fusefuse gL/gG: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1316-2AP00 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Side-by-side mountingYes
3RT1316-2AP00 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1316-2AP00 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Installation altitude, max.2 000 m
3RT1316-2AP00 — Mechanical
ParameterValue
Width45 mm
Height60 mm
Depth72 mm

Product details

It carries 4 NO main contacts across 4 poles, rated for 4 kW at 400 V in AC-2 duty (slip-ring motor starting) and AC-3 (squirrel-cage motor). The main circuit uses spring-loaded terminals, accepting solid or stranded conductors 2x 0.25 to 2.5 mm².

At 45 mm wide, 60 mm tall, and 72 mm deep, this contactor fits a standard DIN-rail enclosure with side-by-side mounting permitted — no spacing required between units. Front and terminal protection is IP20, suitable for enclosed panels where accidental finger contact is the main concern.

Motor switching and coordination

The 4 kW rating at 400 V AC-2/AC-3 covers typical small three-phase motors up to that power. For type 2 coordination (no welding, ready for immediate reuse) use a 20 A gL/gG fuse. Auxiliary contacts handle 10 A at 24 V, 2 A at 60 V, 1 A at 110 V, and 0.3 A at 220 V — enough for PLC inputs or relay coils in the control circuit.

Frequently asked questions

What is the closest functional second-source?

The 3RT1016-2AP02 is a similar SIRIUS Size S00 4-pole contactor, but its terminal type and coil voltage may differ. Verify the coil rating and terminal style before substituting into an existing panel design.

What wire sizes does the spring-loaded terminal accept?

Solid or stranded 2x 0.25 to 2.5 mm² (2x 24 to 14 AWG). Finely stranded with ferrule: 2x 0.25 to 1.5 mm².

What is the mechanical endurance?

30 million operating cycles typical.