Siemens 3RT1316-2BD40 — Contactors

Siemens 3RT1316-2BD40 SIRIUS Power Contactor, S00, 4 NO, 4 k

MPN3RT1316-2BD40

Siemens SIRIUS power contactor, size S00, 3RT1316-2BD40, 4 NO main contacts, 4 kW rated at AC-2 400 V, spring-loaded terminals, snap-on DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1316-2BD40 — Identification
ParameterValue
Contactor frame sizeS00
3RT1316-2BD40 — Ratings & Performance
ParameterValue
Rated value @ 400 V3 A
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1316-2BD40 — Control & Coil
ParameterValue
Control supply voltage typeDC
3RT1316-2BD40 — Contacts & Poles
ParameterValue
Main poles4
Main NO contacts4
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1316-2BD40 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 35 A
Short-circuit coordination type 2, fusefuse gL/gG: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1316-2BD40 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Side-by-side mountingYes
3RT1316-2BD40 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1316-2BD40 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1316-2BD40 — Mechanical
ParameterValue
Width45 mm
Height60 mm
Depth72 mm

Product details

Its 4 normally open main contacts and spring-loaded terminals (accepting 2x 0.25–2.5 mm² solid or stranded) allow for quick wiring without screwdriver torque checks — a time-saver on repetitive panel builds.

Rated 4 kW at AC-2 duty on 400 V, this contactor handles wound-rotor motors and slip-ring applications where moderate inrush and frequent switching are expected. That 4 kW figure is the real-world motor rating — not the resistive AC-1 number — so it governs the motor nameplate you can connect. For coordination, Type 1 requires a 35 A gL/gG fuse upstream; Type 2 needs a 20 A gL/gG fuse. This affects your short-circuit protection scheme — Type 2 limits contactor damage after a fault, while Type 1 allows replacement after a fault. Choose based on your maintenance philosophy. The coil holds at 42 V rated value with a closing and holding power of 3.3 W DC, meaning a standard 24 VDC supply can drive it through a PLC output, but verify the pull-in voltage (0.85 x rated) and drop-out (1.1 x rated) margins against your control voltage stability.

The IP20 finger-safe protection on the front and terminals means it's suitable for enclosed cabinets where personnel access is controlled. Operates from -25 °C to +60 °C, with a maximum altitude of 2,000 m and pollution degree 3.

Frequently asked questions

What is the depth of this contactor?

The depth is 72 mm, with a width of 45 mm and height of 60 mm, fitting standard S00 envelope dimensions.

What wire sizes does the spring-loaded terminal accept?

It accepts 2x 0.25–2.5 mm² solid or stranded (2x 24–14 AWG), and 2x 0.25–1.5 mm² finely stranded with ferrule.

MPN
3RT1316-2BD40