Siemens 3RT1317-1AH00 — Contactors

Siemens SIRIUS 3RT1317-1AH00 Power Contactor, S00, 4NO, 5.5

MPN3RT1317-1AH00

Siemens SIRIUS power contactor, size S00, 4-pole NO main contacts, 5.5 kW at AC-2 400 V, screw terminals, 45 x 57.5 x 72 mm.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1317-1AH00 — Identification
ParameterValue
Contactor frame sizeS00
3RT1317-1AH00 — Ratings & Performance
ParameterValue
Rated value @ 400 V3 A
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1317-1AH00 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz48 V
3RT1317-1AH00 — Contacts & Poles
ParameterValue
Main poles4
Main NO contacts4
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1317-1AH00 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 35 A
Short-circuit coordination type 2, fusefuse gL/gG: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1317-1AH00 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Side-by-side mountingYes
3RT1317-1AH00 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1317-1AH00 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1317-1AH00 — Mechanical
ParameterValue
Width45 mm
Height57.5 mm
Depth72 mm

Product details

The Siemens SIRIUS 3RT1317-1AH00 is a size S00 power contactor with four normally-open main contacts, rated for 5.5 kW at AC-2 duty on 400 V. AC-2 is the standard for slip-ring motor starting and switching — the contactor handles the inrush and the higher switching frequency of wound-rotor motors without excessive contact wear. The 4-pole NO arrangement means it makes all four poles on pickup; there are no normally-closed main contacts on this variant, so it is a straight make-only device for motor or resistive loads where you need to switch all phases plus the neutral. The auxiliary contact block is rated for 10 A at 24 V, 6 A at 230 V, and 3 A at 400 V — these are the thermal current (AC-12) limits for the control circuit. For inductive DC loads, the ratings drop to 2 A at 60 V and 0.3 A at 220 V, which is typical for contactor auxiliaries and reflects the arc-extinction challenge on DC. If you are switching a DC solenoid or brake coil, stay within those limits or add a free-wheel diode. If this contactor sits in a steel-mill pulpit with HVAC, it is fine; if it is mounted on the mill floor near the rolls, you need to check the enclosure ambient.

The S00 footprint is 45 mm wide, 57.5 mm tall, and 72 mm deep — compact enough for dense panel layouts. Screw-type terminals on the main circuit accept 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or up to 2x (0.75 to 4 mm²) — or 1x 12 AWG. The control circuit uses the same terminal range. For Type 1 coordination, the maximum fuse is 35 A gL/gG; for Type 2 coordination (no welding of contacts on fault), it is 20 A gL/gG. That is the short-circuit protection the upstream breaker or fuse must provide to keep the contactor repairable after a fault.

Frequently asked questions

What are the main contact ratings for this contactor?

It has four normally-open main contacts. The motor-switching rating is 5.5 kW at AC-2 duty on 400 V. The auxiliary contacts are rated for 10 A at 24 V, 6 A at 230 V, and 3 A at 400 V (AC-12).

What wire sizes does the screw terminal accept?

The screw terminals accept 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or up to 2x (0.75 to 4 mm²) solid or stranded, or 1x 12 AWG.

What is the short-circuit protection requirement?

For Type 1 coordination, use a 35 A gL/gG fuse. For Type 2 coordination (no contact welding), use a 20 A gL/gG fuse.

MPN
3RT1317-1AH00