Siemens 3RT1325-1BM40-ZX95 — Contactors

Siemens 3RT1325-1BM40-ZX95 SIRIUS Power Contactor, S0, 4NO,

MPN3RT1325-1BM40-ZX95

Siemens SIRIUS power contactor, size S0, 4 NO main contacts, 7.5 kW at AC-2 400 V, screw terminals, snap-on DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1325-1BM40-ZX95 — Identification
ParameterValue
Contactor frame sizeS0
3RT1325-1BM40-ZX95 — Ratings & Performance
ParameterValue
Rated value @ 400 V3 A
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1325-1BM40-ZX95 — Control & Coil
ParameterValue
Control supply voltage typeDC
3RT1325-1BM40-ZX95 — Contacts & Poles
ParameterValue
Main poles4
Main NO contacts4
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1325-1BM40-ZX95 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 63 A
Short-circuit coordination type 2, fusefuse gL/gG: 25 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1325-1BM40-ZX95 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Side-by-side mountingYes
3RT1325-1BM40-ZX95 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1325-1BM40-ZX95 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1325-1BM40-ZX95 — Mechanical
ParameterValue
Width61 mm
Height85 mm
Depth101 mm

Product details

SIRIUS S0 power contactor for motor and resistive loads

It carries 4 normally open main contacts and is rated for screw-type terminal connections. Rated at 7.5 kW at AC-2 duty on 400 V, this contactor is sized for moderate motor applications like pumps, fans, and compressors where starting current and load disconnection are regular events. The AC-2 rating covers slip-ring motor switching with moderate overloads.

The S0 footprint occupies 61 mm width, 85 mm height, and 101 mm depth — a compact envelope that fits standard panel layouts without crowding adjacent devices. Side-by-side mounting is permitted, which simplifies multi-contactor assemblies for star-delta or reversing starters. Wire capacity for main circuit terminals: accepts solid conductors 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), and up to 2x (0.75 to 4 mm²) maximum. For stranded or finely stranded wire with ferrules, the range is 2x (0.5 to 1.5 mm²) and 2x (0.75 to 2.5 mm²). AWG equivalents are 2x (20 to 16) and 2x (18 to 14) for solid, with a single 12 AWG maximum.

Type 1 coordination (contactor may need replacement after fault) allows a 63 A gL/gG fuse. This lets the panel designer balance protection selectivity against component survival. DC coil closing and holding power are both 5.4 W, which simplifies power supply sizing for the control circuit.

Frequently asked questions

What are the key ratings for this contactor?

The contactor is rated 7.5 kW at AC-2 400 V for motor loads, and 10 A at AC-12 for resistive loads. It has 4 normally open main contacts, a mechanical endurance of 10,000,000 cycles, and operates from -25 to +60 °C.

What wire sizes does the main circuit terminal accept?

Solid conductors: 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), max 2x (0.75 to 4 mm²). Finely stranded with ferrules: 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²). AWG equivalents: 2x (20 to 16), 2x (18 to 14), and 1x 12.

What are the short-circuit protection requirements?

Type 2 coordination requires a 25 A gL/gG fuse upstream. Type 1 coordination allows a 63 A gL/gG fuse.

MPN
3RT1325-1BM40-ZX95