Siemens 3RT1325-3XF48-0LA3 — Contactors

Siemens SIRIUS 3RT1325-3XF48-0LA3 Power Contactor, S0, 4-Pol

MPN3RT1325-3XF48-0LA3

Siemens SIRIUS power contactor, size S0, 3RT1325-3XF48-0LA3, 4 NO main contacts, 7.5 kW AC-2 at 400 V, 110 V DC coil with varistor, screw terminals, IP20 front, 71 mm width.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1325-3XF48-0LA3 — Identification
ParameterValue
Contactor frame sizeS0
3RT1325-3XF48-0LA3 — Ratings & Performance
ParameterValue
Rated value @ 400 V3 A
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1325-3XF48-0LA3 — Control & Coil
ParameterValue
Control supply voltage typeDC
3RT1325-3XF48-0LA3 — Contacts & Poles
ParameterValue
Main poles4
Main NO contacts4
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1325-3XF48-0LA3 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 63 A
Short-circuit coordination type 2, fusefuse gL/gG: 25 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1325-3XF48-0LA3 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Side-by-side mountingYes
3RT1325-3XF48-0LA3 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1325-3XF48-0LA3 — Environmental
ParameterValue
Operating temperature range-40 ... +70 °C
3RT1325-3XF48-0LA3 — Mechanical
ParameterValue
Width71 mm
Height119 mm
Depth101 mm

Product details

The Siemens SIRIUS 3RT1325-3XF48-0LA3 is a size S0 power contactor with four normally-open main contacts, rated at 7.5 kW for AC-2 duty at 400 V — that's the motor-switching rating for slip-ring or wound-rotor motors, where the load current stays high through the opening arc. The 110 V DC coil includes a built-in varistor surge suppressor, so you don't need to add an external snubber on the coil circuit.

The 7.5 kW AC-2 at 400 V rating governs the real motor load this contactor can switch — AC-2 is the category for starting and plugging of slip-ring motors, where the contactor must interrupt the rotor current at standstill. For AC-12 resistive loads (heater, lighting) it's rated at 10 A maximum. Type 1 coordination allows up to 63 A. That's the fuse sizing you need to protect the contactor during a bolted fault — Type 2 means the contactor remains usable after clearing the fault, Type 1 means it may need replacement. The contactor mounts on a 35 mm DIN rail per EN 50022, either screw-fixed or snap-on, and fits a standard S0 footprint — 71 mm wide, 119 mm high, 101 mm deep. The main circuit terminals are screw-type, accepting up to 2x 10 mm² or 1x AWG 12 solid/stranded — the wire range is 0.25 to 2.5 mm² for the auxiliary contacts (2x conductors).

Frequently asked questions

What is the depth of this contactor?

The depth is 101 mm, which includes the terminal overhang. That's the dimension you need for enclosure depth clearance.

What wire sizes does the main circuit accept?

Screw terminals accept 2x (1 to 2.5 mm²), 2x (2.5 to 6 mm²), or up to 2x 10 mm² solid/stranded. AWG equivalents: 2x (20 to 16), 2x (18 to 14), or 1x 12.

Will this contactor drop into a panel designed for 3RT1023-1AL20?

Both are S0 frame size and mount on 35 mm DIN rail, so the footprint matches. But verify the coil voltage — the 3RT1325-3XF48-0LA3 uses 110 V DC, while the 3RT1023-1AL20 may differ. Also check the main contact count: this unit has 4 NO contacts; the peer may have a different NO/NC mix.

MPN
3RT1325-3XF48-0LA3