Skip to main content
Siemens 3RT1446-1AB00 — Contactors

Siemens SIRIUS 3RT1446-1AB00 power contactor, S3, 22 kW AC-2

MPN3RT1446-1AB00

Siemens SIRIUS power contactor, size S3, 3RT1446-1AB00, rated 22 kW at AC-2 400 V, screw-type terminals, snap-on mounting.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1446-1AB00 — Identification
ParameterValue
Contactor frame sizeS3
3RT1446-1AB00 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated value @ 400 V3 A
Rated value @ 500 V29.9 kW
Rated value @ 690 V38.2 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1446-1AB00 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz24 V
3RT1446-1AB00 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1446-1AB00 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 250 A
Short-circuit coordination type 2, fuseFuse gR: 250 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1446-1AB00 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (2.5 ... 16 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm and 75 mm standard mounting rail
Side-by-side mountingYes
3RT1446-1AB00 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1446-1AB00 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1446-1AB00 — Mechanical
ParameterValue
Width70 mm
Height146 mm
Depth139 mm
3RT1446-1AB00 — Specifications
ParameterValue
At AC10 ... 25 ms

Product details

The Siemens SIRIUS 3RT1446-1AB00 is a size S3 power contactor rated for motor switching at 22 kW under AC-2 duty at 400 V, and delivers 38.2 kW at 690 V.

The AC-2 rating at 400 V (22 kW) is the figure that governs motor switching for slip-ring or wound-rotor motors — AC-2 duty involves starting and plugging, so the contactor is designed for higher inrush and longer arcing than a general-purpose AC-3 unit. The 690 V rating (38.2 kW) covers higher-voltage distribution common in European industrial plants. At 60 °C ambient, the contactor derates to 50 kW at 230 V and 148 kW at 690 V, so if the panel runs hot, use the 60 °C column for sizing. Mechanical life is typical 10,000,000 operations, and the maximum switching rate at AC-1 resistive load is 650 cycles per hour. The coil operates at 50 Hz, 24 V, with a pick-up dropout range of 0.8 to 1.1 times rated voltage at 50 Hz. The auxiliary contact ratings cover 10 A at 24 V, 6 A at 230 V, and 3 A at 400 V, so the same contact block can handle PLC-level signals or small relay coils without a separate interface.

Installation and wiring

Screw-type terminals on the main circuit accept stranded conductors up to 2x 50 mm², and solid conductors from 0.5 mm² to 4 mm² in the control circuit. The terminal block itself is rated IP00 (open), but with the supplied cover or box terminal, the front face achieves IP20 — finger-safe for live panel access. At 40 °C ambient, the minimum permissible conductor cross-section is 50 mm²; at 60 °C, it drops to 35 mm² — this is a thermal derating guide for the main power path, not a wiring restriction. The insulation voltage is rated 1,000 V, which means the contactor can be used in 690 V systems with adequate clearance.

Frequently asked questions

What compliance documentation does this contactor carry?

RoHS compliance date is May 1, 2012. The insulation voltage is rated 1,000 V, and the pollution degree is 3, which aligns with IEC 60947-4-1 requirements for industrial motor control.

What is the closest functional second-source to this contactor?

The 3RT1034-1AN60-1AA0 is a smaller frame (S0) contactor from the same SIRIUS family, but it does not match the S3 frame size or the 22 kW AC-2 rating of the 3RT1446-1AB00. A panel wired for the S3 footprint would require mechanical rework to accept the smaller unit.

MPN
3RT1446-1AB00