3RT1446-1BG40 — Identification
ParameterValue
Contactor frame sizeS3
3RT1446-1BG40 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated value @ 400 V3 A
Rated value @ 500 V29.9 kW
Rated value @ 690 V38.2 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1446-1BG40 — Control & Coil
ParameterValue
Control supply voltage typeDC
3RT1446-1BG40 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1446-1BG40 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 250 A
Short-circuit coordination type 2, fuseFuse gR: 250 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1446-1BG40 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (2.5 ... 16 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm and 75 mm standard mounting rail
Side-by-side mountingYes
3RT1446-1BG40 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1446-1BG40 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1446-1BG40 — Mechanical
ParameterValue
Width70 mm
Height146 mm
Depth152 mm

Product details

Its key motor ratings are 22 kW at AC-2 duty on 400 V and 38.2 kW at 690 V — the 690 V figure is the one that matters for 690 V line-fed drives or transformers, while the AC-2 rating governs slip-ring motor switching where starting current is higher than a standard squirrel-cage. It accepts stranded conductors up to 2x 50 mm², and at 40 °C ambient the minimum permissible cable is 50 mm² — meaning you don't need to oversize the lug for thermal headroom. Side-by-side mounting is permitted, which keeps the row width tight when ganging multiple contactors for a multi-motor group.

The S3 frame is a mid-range contactor body — 146 mm high, 70 mm wide, 152 mm deep — sized for motors in the 30–50 kW range depending on voltage and duty. The 690 V rating at 60 °C ambient (148 kW) shows this contactor can handle high-voltage, high-power loads, but the 60 °C derating curve means the terminal capacity drops to 35 mm² minimum at that temperature — so if your panel runs hot, you still land 35 mm² cable without splicing. The front face carries IP20 with the cover or box terminal fitted; the terminal itself is IP00, meaning the wiring compartment needs enclosure protection in washdown areas. Mechanical life is 10,000,000 operations typical, and the maximum switching rate at AC-1 resistive load is 650 cycles per hour. That's a fast mover for a contactor this size — it can keep pace with a cycling load like a compressor or a rapid-index conveyor without wearing out the armature prematurely.

The substance prohibitance date is 05/01/2012, which aligns with RoHS compliance for the European market.

Frequently asked questions

What are the key motor power ratings for this contactor?

At AC-2 duty on 400 V it is rated for 22 kW. At 690 V the rating is 38.2 kW. At 230 V and 60 °C ambient it can handle 50 kW, and at 690 V and 60 °C it reaches 148 kW.

What wire sizes does the screw terminal accept?

The main terminals accept stranded conductors up to 2x 50 mm². For solid wire, it accepts 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), and up to 2x (0.75 to 4 mm²). The minimum permissible cable at 40 °C is 50 mm², and at 60 °C it drops to 35 mm².

Does it mount on standard DIN rail?

Yes, it mounts via screw and snap-on onto 35 mm and 75 mm standard mounting rail. Side-by-side mounting is also permitted.

What is the mechanical life expectancy?

Typical mechanical life is 10,000,000 operations. The maximum switching rate at AC-1 resistive load is 650 cycles per hour.