Siemens 3RT1466-6AD36 — Contactors

Siemens 3RT1466-6AD36 SIRIUS Contactor, Size S10, 42-48 V AC

MPN3RT1466-6AD36
Active

Siemens SIRIUS Size S10 contactor, order code 3RT1466-6AD36, 42-48 V AC/DC coil, screw-type terminals, 70-240 mm² stranded main circuit wiring, 202 mm depth.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RT1466-6AD36 — Identification
ParameterValue
Contactor frame sizeS10
3RT1466-6AD36 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1466-6AD36 — Control & Coil
ParameterValue
Control supply voltage typeAC/DC
Rated value @ 50 Hz0.9
Rated value @ 50 Hz42 ... 48 V
3RT1466-6AD36 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1466-6AD36 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 500 A (690 V, 100 kA)
Short-circuit coordination type 2, fusegR: 500 A (690 V, 100 kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT1466-6AD36 — Connection & Mounting
ParameterValue
Main circuit connectionConnection bar
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew fixing
Side-by-side mountingYes
3RT1466-6AD36 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1466-6AD36 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1466-6AD36 — Mechanical
ParameterValue
Width145 mm
Height210 mm
Depth202 mm
3RT1466-6AD36 — Specifications
ParameterValue
At AC40 ... 80 ms

Product details

SIRIUS Size S10 — what the frame rating means for your panel

The 3RT1466-6AD36 is a Siemens SIRIUS Size S10 contactor — the S10 frame is the largest standard size in the SIRIUS modular contactor range, sized for high-current motor switching and heavy industrial loads up to the full rating of the frame. The Size S10 designation tells you the physical envelope and the maximum thermal continuous current the contactor can handle; it governs the main power lug capacity, which on this unit accepts stranded conductors from 70 mm² up to 240 mm², so it is built for feeders and large motor branch circuits, not small panel auxiliaries. Mounting is screw fixing with a vertical mounting surface — the contactor can be rotated ±90° and tilted ±22.5° front-to-back, which gives flexibility in tight enclosures or when aligning with busbar systems. The 210 mm height, 145 mm width, and 202 mm depth mean it occupies a full-size footprint; plan for a 10 mm clearance above and below and 20 mm forward clearance for arc-chamber venting (arcing time is 10-15 ms). The coil is rated 42-48 V AC/DC with pickup at 80% of rated value and dropout below the hold threshold — operate time is 40-80 ms on both AC and DC, consistent for sequencing interlocking.

Coil and auxiliary circuit — what the 42-48 V AC/DC rating drives

The coil is screw-type terminals, accepting solid or stranded wire: 2x 0.5-1.5 mm², 2x 0.75-2.5 mm², or max 2x 0.75-4 mm². That is a standard control-circuit termination — compatible with most PLC digital outputs and relay interposing panels. The 42-48 V AC/DC coil voltage is common in industrial control systems using 48 V DC control buses or 42 V AC derived from control transformers; verify your control supply matches before wiring. The contactor ships with an auxiliary switch block (4 contacts attachable). The auxiliary contacts are rated: 10 A at 24 V, 2 A at 48 V, 2 A at 60 V, 1 A at 110 V, 0.9 A at 125 V, 0.3 A at 220 V, and 6 A at 230 V — the ratings drop with voltage due to arc extinction limits. For a 24 V DC PLC input circuit, the 10 A rating gives generous headroom for multiple feedback signals.

Frequently asked questions

What is the closest functional second-source to 3RT1466-6AD36?

The closest functional peer is the 3RT1264-6AP36-0KA1, which is also a Size S10 SIRIUS contactor. The key difference is the coil voltage: the 3RT1466-6AD36 uses a 42-48 V AC/DC coil, while the 3RT1264-6AP36-0KA1 uses a different coil voltage. Panel fit and power lug capacity are identical — a panel wired for one can accept the other without rewiring the main circuit, provided the control voltage matches.

Will 3RT1466-6AD36 drop into a panel specified around 3RT1264-6AP36-0KA1 without rewiring?

Yes, the physical footprint and power terminations are identical — both are Size S10 with the same 210 mm height, 145 mm width, 202 mm depth, and 70-240 mm² stranded main lug capacity. The only difference is the coil voltage; verify your control circuit supplies 42-48 V AC/DC before substitution.

What is the depth of 3RT1466-6AD36?

The depth is 202 mm. This is the dimension from the mounting surface to the furthest forward point of the contactor body, excluding arc-chamber clearance (20 mm forward required).

What wire sizes does the main power circuit accept?

The main power lugs accept stranded copper conductors from 70 mm² up to 240 mm². The control circuit (coil and auxiliary) accepts 2x 0.5-1.5 mm², 2x 0.75-2.5 mm², or max 2x 0.75-4 mm² solid or stranded.