Specifications

3RT1466-6LA06 — Identification
ParameterValue
Contactor frame sizeS10
3RT1466-6LA06 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1466-6LA06 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1466-6LA06 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 500 A (690 V, 100 kA)
Short-circuit coordination type 2, fusegR: 500 A (690 V, 100 kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT1466-6LA06 — Connection & Mounting
ParameterValue
Main circuit connectionConnection bar
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew fixing
Side-by-side mountingYes
3RT1466-6LA06 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1466-6LA06 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1466-6LA06 — Mechanical
ParameterValue
Width145 mm
Height210 mm
Depth202 mm
3RT1466-6LA06 — Specifications
ParameterValue
At AC40 ... 80 ms

Product details

The auxiliary contacts are rated for switching at 24 VDC up to 10 A, at 230 VAC up to 6 A, and at 400 VAC up to 3 A — so it can handle both the coil circuit of a downstream contactor and a PLC digital input signal on the same block.

Fastens with screw fixing through an 11 mm hole. The mounting position allows vertical surface mounting with ±90° rotation or ±22.5° tilt front-to-back, so it fits into tight enclosures where the panel isn't perfectly vertical. Power terminals accept stranded cable from 70 to 240 mm² — that's heavy cable, sized for the full rated current of the S10 frame. The auxiliary terminals take 2x 0.5 to 1.5 mm² solid or 2x 0.75 to 2.5 mm² stranded, max 2x 4 mm². Side-by-side mounting is allowed, with 10 mm clearance to the side and 10 mm upward/downward. Overall dimensions: 210 mm high, 145 mm wide, 202 mm deep. That depth is the body plus the arc chamber — plan for at least 20 mm forward clearance for wiring and arc venting.

Frequently asked questions

What is the depth of this contactor?

202 mm body depth, plus 20 mm forward clearance recommended for wiring access and arc venting.

What wire sizes does the auxiliary terminal block accept?

Solid: 2x 0.5 to 1.5 mm² or 2x 0.75 to 2.5 mm², max 2x 4 mm². Stranded power terminals accept 70 to 240 mm².

Will 3RT1466-6LA06 drop into a panel designed for 3RT1076-6AP36?

Both are SIRIUS S10 frame contactors with the same mounting hole pattern and similar dimensions. The 3RT1466-6LA06 carries an integrated 2 NO + 2 NC auxiliary block, while the 3RT1076-6AP36 may have a different auxiliary configuration — check the existing panel's auxiliary contact count before swapping.