Skip to main content
Siemens 3RT1466-6NP36 — Contactors

Siemens 3RT1466-6NP36 SIRIUS Contactor, S10 Size, 200-277V A

MPN3RT1466-6NP36
Active

Siemens SIRIUS contactor, size S10, 3RT1466-6NP36, 200-277 V AC/DC coil, screw-type terminals, 10 million mechanical cycles.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RT1466-6NP36 — Identification
ParameterValue
Contactor frame sizeS10
3RT1466-6NP36 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1466-6NP36 — Control & Coil
ParameterValue
Control supply voltage typeAC/DC
Rated value @ 50 Hz0.5
Rated value @ 50 Hz200 ... 277 V
3RT1466-6NP36 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1466-6NP36 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 500 A (690 V, 100 kA)
Short-circuit coordination type 2, fusegR: 500 A (690 V, 100 kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT1466-6NP36 — Connection & Mounting
ParameterValue
Main circuit connectionConnection bar
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew fixing
Side-by-side mountingYes
3RT1466-6NP36 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1466-6NP36 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1466-6NP36 — Mechanical
ParameterValue
Width145 mm
Height210 mm
Depth202 mm
3RT1466-6NP36 — Specifications
ParameterValue
At AC80 ... 100 ms

Product details

The coil accepts 200–277 V AC/DC, so it works on either supply without a separate rectifier — simplifies panel wiring when both AC and DC control voltages are present.

Mounts via screw fixing (two 11 mm holes on 145 mm width) onto a vertical panel surface. Dimensions: 210 mm high, 145 mm wide, 202 mm deep. The depth is the main panel-space constraint — allow at least 10 mm clearance at the side and 20 mm forward for arc-chamber venting and wiring access. Main power terminals accept stranded conductors from 70 to 240 mm² — sized for the full S10 current rating. Auxiliary terminals handle 2x (0.5–1.5 mm²) solid or 2x (0.75–2.5 mm²) stranded, with a max of 2x (0.75–4 mm²). Coil connections are screw-type terminals, not cage clamps.

Frequently asked questions

What are the key ratings for this contactor?

Coil voltage 200–277 V AC/DC, mechanical endurance 10 million cycles, operating temperature -25 to +60 °C, storage -55 to +80 °C. Main power terminals accept 70–240 mm² stranded wire.

Will 3RT1466-6NP36 drop into a panel specified for 3RT1076-6AP36?

Both are S10 frame size with the same mounting hole pattern (11 mm diameter, 145 mm width) and screw fixing. The coil voltage differs — 3RT1466-6NP36 uses 200–277 V AC/DC, while 3RT1076-6AP36 may use a different coil. Check the coil rating before substitution; mechanical fit is the same.

MPN
3RT1466-6NP36