Siemens 3RT1517-1AN20 — Contactors

Siemens 3RT1517-1AN20 SIRIUS Power Contactor, S00, 220 VAC C

MPN3RT1517-1AN20

Siemens SIRIUS 3RT1517-1AN20 power contactor, size S00, 220 VAC 50/60 Hz coil, screw-type terminals, 45 mm width, current production.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RT1517-1AN20 — Identification
ParameterValue
Contactor frame sizeS00
3RT1517-1AN20 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated value @ 400 V3 A
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1517-1AN20 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz4.4 V·A
Rated value @ 50 Hz220 V
3RT1517-1AN20 — Contacts & Poles
ParameterValue
Main poles4
Main NO contacts2
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1517-1AN20 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 35 A
Short-circuit coordination type 2, fusefuse gL/gG: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1517-1AN20 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Side-by-side mountingYes
3RT1517-1AN20 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1517-1AN20 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1517-1AN20 — Mechanical
ParameterValue
Width45 mm
Height57.5 mm
Depth72 mm
3RT1517-1AN20 — Specifications
ParameterValue
At AC4 ... 30 ms

Product details

Part Identity and Deployment Context

This form factor suits compact control panels where panel density and DIN-rail integration are primary constraints. The contactor measures 45 mm wide, 57.5 mm high, and 72 mm deep, fitting into the S00 footprint that is common across the SIRIUS 3RT1 series for motor loads up to the contactor's rated operational current.

The coil is rated for 220 V at both 50 Hz and 60 Hz, drawing 4.4 V·A at 50 Hz and a power factor of 0.27 at 60 Hz. This means the control transformer supplying the coil must be sized for the inrush, not just the sealed VA — a common oversight during panel design. Auxiliary contact ratings are provided for several DC voltages: 10 A at 24 V, 2 A at 60 V, 1 A at 110 V, 0.3 A at 220 V, and 0.8 A at 440 V. Each NO and NC auxiliary contact is rated for 12 A continuous current. These values govern the signal-level switching capability for PLC inputs, indicator lamps, and interposing relays in the control circuit.

Main Circuit and Wiring

Main and auxiliary circuits use screw-type terminals. The main circuit accepts solid or stranded conductors: 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or a maximum of 2x (0.75 to 4 mm²). For AWG, the terminals accept 2x (20 to 16), 2x (18 to 14), or 1x 12. The auxiliary and control circuit terminals share the same screw-type design. The manufacturer specifies a required fuse of gL/gG type rated at 20 A for type of assignment 2 coordination. This ensures that under short-circuit conditions, the contactor is protected without damage to the starter assembly — a coordination requirement that must match the upstream protective device.

This wide span covers most indoor industrial environments and unheated warehouses. These values matter for sequencing logic where contactor dropout timing affects downstream safety interlocks.

The product carries a RoHS compliance date of 01 July 2006, indicating it meets the EU Restriction of Hazardous Substances directive. Substance prohibitance is documented per the manufacturer's declaration. As a SIRIUS component, the 3RT1517-1AN20 is supported by the full Siemens technical documentation package including a datasheet, dimension drawings, circuit diagrams, and EC declaration of conformity, which can be provided with the shipment for quality documentation traceability.

Frequently asked questions

What are the key ratings for the 3RT1517-1AN20?

The contactor has a 220 VAC 50/60 Hz coil drawing 4.4 V·A at 50 Hz, auxiliary contact ratings including 10 A at 24 VDC and 6 A at 230 VAC, and each NO/NC contact rated for 12 A continuous. Main circuit impulse withstand is 6 kV.

What wire sizes does the 3RT1517-1AN20 accept?

Screw terminals accept solid or stranded conductors: 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or max 2x (0.75 to 4 mm²). AWG equivalents are 2x (20 to 16), 2x (18 to 14), or 1x 12.

What is the mounting method for this contactor?

It mounts via screw and snap-on onto a 35 mm standard mounting rail per DIN EN 50022, with side-by-side mounting permitted at 6 mm clearance.

What compliance documentation is available for the 3RT1517-1AN20?

The product meets RoHS requirements with a compliance date of 01 July 2006. Full Siemens documentation including datasheet, dimension drawings, and EC declaration of conformity is available with the order.

MPN
3RT1517-1AN20