Siemens 3RT1517-2AK60 — Contactors

Siemens 3RT1517-2AK60 SIRIUS Power Contactor, S00, 24 VDC Co

MPN3RT1517-2AK60

Siemens SIRIUS power contactor, size S00, 3RT1517-2AK60, 24 VDC coil rated 10 A, spring-loaded terminals, 45 mm width, snap-on DIN-rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1517-2AK60 — Identification
ParameterValue
Contactor frame sizeS00
3RT1517-2AK60 — Ratings & Performance
ParameterValue
Rated value @ 400 V3 A
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1517-2AK60 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz5.1 V·A
Rated value @ 50 Hz110 V
3RT1517-2AK60 — Contacts & Poles
ParameterValue
Main poles4
Main NO contacts2
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1517-2AK60 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 35 A
Short-circuit coordination type 2, fusefuse gL/gG: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1517-2AK60 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Side-by-side mountingYes
3RT1517-2AK60 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1517-2AK60 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
3RT1517-2AK60 — Mechanical
ParameterValue
Width45 mm
Height60 mm
Depth72 mm
3RT1517-2AK60 — Specifications
ParameterValue
At AC4 ... 30 ms

Product details

That 10 A coil draw at 24 VDC is the burden on the control transformer or PLC output driving it; the contactor itself is rated to switch motor loads up to the contactor's AC-3 rating, which for this frame typically lands around 7 A at 400 V for a 3 kW motor. Spring-loaded terminals on the main circuit accept 2x (0.25... 2.5 mm²) solid or stranded, so it terminates into standard control wiring without ferrules if you strip to 8 mm. The 45 mm width and snap-on mounting onto 35 mm DIN rail per EN 50022 means it fits a standard panel footprint — side-by-side mounting is permitted, so you can gang several on the same rail without derating the enclosure's thermal budget provided you stay within the rated operating temperature range of -25... +60 °C.

Coil and switching ratings

The coil is rated for 110 V at 50 Hz and 120 V at 60 Hz, with a holding power of 5.1 V·A at 50 Hz. The arcing time across the main contacts runs 10... 15 ms — that's the interval the arc extinguishes after the contacts part, which matters for coordination with upstream fuses or breakers in a motor branch circuit. Switching frequency at AC-1 (resistive load) maxes out at 1 000 operations per hour; for motor duty (AC-3) you'd derate that significantly — the mechanical life of 30 000 000 operations is the limit before wear, not the electrical life under load.

The mounting position allows vertical surface with +/-180° rotation and +/-30° tilt forward/back — so you can orient it in a tight cabinet as long as the coil's magnetic circuit isn't fighting gravity. Storage temperature range is -55... +80 °C, operating range -25... +60 °C.

Frequently asked questions

Where can I buy the 3RT1517-2AK60 and get a price?

This part is sourced to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What is the 3RT1517-2AK60's depth?

The depth is 72 mm.

What wire size does the 3RT1517-2AK60 accept?

The spring-loaded terminals accept 2x (0.25... 2.5 mm²) solid or stranded conductors.

Will the 3RT1517-2AK60 drop into a panel specified for the 3RT1016-2AP02 without rewiring?

Both are size S00 contactors on a 45 mm width with snap-on DIN-rail mounting, so the footprint and rail position are identical. The 3RT1517-2AK60 uses spring-loaded terminals while the 3RT1016-2AP02 uses screw terminals — if the panel was wired with ferruled stranded conductors for screw clamps, those same conductors may need re-termination for the spring cage (strip length and ferrule compatibility differ). The coil voltage must also match: the 3RT1517-2AK60 is a 24 VDC coil, so verify the control voltage matches the existing circuit.

MPN
3RT1517-2AK60