Siemens 3RT1517-2AM20 — Contactors

Siemens 3RT1517-2AM20 SIRIUS Power Contactor, Size S00, 24 V

MPN3RT1517-2AM20

Siemens SIRIUS 3RT1517-2AM20 power contactor, Size S00, 24 VDC coil rated 10 A, spring-loaded terminals, screw and snap-on mounting onto 35 mm DIN rail.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RT1517-2AM20 — Identification
ParameterValue
Contactor frame sizeS00
3RT1517-2AM20 — Ratings & Performance
ParameterValue
Rated value @ 400 V3 A
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1517-2AM20 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz4.4 V·A
Rated value @ 50 Hz208 V
3RT1517-2AM20 — Contacts & Poles
ParameterValue
Main poles4
Main NO contacts2
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1517-2AM20 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 35 A
Short-circuit coordination type 2, fusefuse gL/gG: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1517-2AM20 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Side-by-side mountingYes
3RT1517-2AM20 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1517-2AM20 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
3RT1517-2AM20 — Mechanical
ParameterValue
Width45 mm
Height60 mm
Depth72 mm
3RT1517-2AM20 — Specifications
ParameterValue
At AC4 ... 30 ms

Product details

Its 24 VDC coil draws 4.4 VA at 50 Hz and 0.27 VA at 60 Hz, with a rated operational current of 10 A at 24 V.

Spring-loaded terminals on the main circuit accept 2x (0.25... 2.5 mm²) solid or stranded — no screw torque to check, which speeds wiring on the line. The auxiliary contacts are rated 12 A per NO/NC, enough for pilot-duty control circuits. Storage range extends to -55 to +80 °C, so spares can sit on a shelf in a non-climate store.

Frequently asked questions

What are the key dimensions for panel layout?

Width 45 mm, height 60 mm, depth 72 mm. It snaps onto 35 mm DIN rail per EN 50022 and allows side-by-side mounting without spacing.

What wire sizes does the spring-loaded terminal accept?

Solid or stranded conductors 2x (0.25... 2.5 mm²) per terminal.

How does this compare to the 3RT1016-2AP02?

Both are SIRIUS Size S00 contactors on the same DIN-rail footprint. The 3RT1517-2AM20 uses spring-loaded terminals; the 3RT1016-2AP02 uses screw terminals. If your panel is already wired with ring lugs, the screw-terminal variant avoids re-termination. For new builds, the spring-loaded version saves install time.

MPN
3RT1517-2AM20