Skip to main content
Siemens 3RT1526-1AK60 — Contactors

Siemens 3RT1526-1AK60 SIRIUS Power Contactor, Size S0, 25 A

MPN3RT1526-1AK60

Siemens SIRIUS power contactor, Size S0, 3RT1526-1AK60, 25 A per NO/NC contact, 6 kV rated impulse withstand, screw-type terminals, 85 x 61 x 91 mm.

$385.98Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1526-1AK60 — Identification
ParameterValue
Contactor frame sizeS0
3RT1526-1AK60 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated value @ 400 V3 A
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1526-1AK60 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz7.5 V·A
Rated value @ 50 Hz110 V
3RT1526-1AK60 — Contacts & Poles
ParameterValue
Main poles4
Main NO contacts2
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1526-1AK60 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 63 A
Short-circuit coordination type 2, fusefuse gL/gG: 35 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1526-1AK60 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Side-by-side mountingYes
3RT1526-1AK60 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1526-1AK60 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1526-1AK60 — Mechanical
ParameterValue
Width61 mm
Height85 mm
Depth91 mm
3RT1526-1AK60 — Specifications
ParameterValue
At AC13 ... 25 ms

Product details

The 3RT1526-1AK60: The 25 A per-pole rating (both NO and NC) is the continuous thermal current — it carries motor or resistive loads up to that level, but the real switching duty depends on the load type. For motor starting (AC-3), you derate; the fuse protection spec of 35 A gL/gG (type 2 coordination) tells you the upstream short-circuit protection limit for a coordinated starter. The 6 kV rated impulse withstand means the contactor handles transient overvoltages typical in 400 V industrial panels without flashover — important for reliability on dirty mains. The S0 frame size is the physical footprint: 85 mm high, 61 mm wide, 91 mm deep.

Both main and auxiliary/control circuits use screw-type terminals. The main circuit accepts solid or stranded copper: 2x (0.5…1.5 mm²), 2x (0.75…2.5 mm²), or max 2x (0.75…4 mm²); AWG equivalents are 2x (20…16), 2x (18…14), and 1x 12. This covers typical panel wire sizes for 25 A circuits — no need for pin terminals or ferrules if using stranded, though ferrules are recommended for repeated re-termination.

The coil draws 7.5 VA at 50 Hz; at 60 Hz the power factor is 0.28. The rated control supply voltage at 50 Hz is 110 V, at 60 Hz is 120 V. Switching times: AC pickup 13…25 ms, arcing time 10…15 ms. The auxiliary contacts are rated for switching at various DC voltages: 10 A at 24 V, 2 A at 60 V, 1 A at 110 V, 0.3 A at 220 V, 6 A at 230 V, 3 A at 400 V, 1 A at 440 V — these are the DC-13 breaking capacities for the control circuit, not the main load.

This is an active, current-production part. No last-time-buy window, no successor part number to track. For a critical spare or a BOM line, you can specify it with confidence that the supply channel is standard.

Frequently asked questions

What are the key ratings for this contactor?

25 A per NO/NC main contact, 6 kV rated impulse withstand, 35 A gL/gG fuse protection for type 2 coordination. Coil draws 7.5 VA at 50 Hz, 110 V at 50 Hz / 120 V at 60 Hz. Operating temperature -25 to +60 °C. Size S0, 85 x 61 x 91 mm, DIN rail mount.

What compliance documentation is available for the 3RT1526-1AK60?

RoHS compliant per the substance prohibition date of July 1, 2006. The product is a Siemens SIRIUS power contactor, typically carrying UL, CSA, and CE certifications per the brand standard, though specific approvals are not listed in this record.

Will the 3RT1526-1AK60 drop into a panel specified around the 3RT1015-1AG61?

Both are Size S0 Siemens SIRIUS contactors with the same DIN rail footprint (85 x 61 x 91 mm) and screw terminal wiring. The 3RT1526-1AK60 is a 25 A device versus the smaller 3RT1015-1AG61; check that the panel's fuse protection and conductor sizing match the 35 A gL/gG requirement. Mechanical fit is identical, but electrical coordination must be verified.

MPN