Siemens 3RT1526-3BB48-0PA8 — Contactors

Siemens 3RT1526-3BB48-0PA8 SIRIUS Power Contactor, Size S0,

MPN3RT1526-3BB48-0PA8

Siemens SIRIUS power contactor, Size S0, 3RT1526-3BB48-0PA8, 24 VDC coil, 3 NO main contacts, screw-type terminals, DIN rail mount, IP20 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1526-3BB48-0PA8 — Identification
ParameterValue
Contactor frame sizeS0
3RT1526-3BB48-0PA8 — Ratings & Performance
ParameterValue
Rated value @ 400 V3 A
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1526-3BB48-0PA8 — Control & Coil
ParameterValue
Control supply voltage typeDC
3RT1526-3BB48-0PA8 — Contacts & Poles
ParameterValue
Main poles4
Main NO contacts2
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1526-3BB48-0PA8 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 63 A
Short-circuit coordination type 2, fusefuse gL/gG: 35 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1526-3BB48-0PA8 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Side-by-side mountingYes
3RT1526-3BB48-0PA8 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1526-3BB48-0PA8 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
3RT1526-3BB48-0PA8 — Mechanical
ParameterValue
Width71 mm
Height85 mm
Depth101 mm

Product details

The kit is complete: the contactor body ships with the terminal hardware for the main and auxiliary circuits — no separate accessory pack needed for a standard install.

Dimensions are 71 mm wide, 85 mm tall, and 101 mm deep — the S0 frame fits standard 35 mm DIN rail enclosures.

Each NO and NC auxiliary contact is rated 20 A continuous. The main circuit handles impulse withstand at 6 kV. Switching frequencies reach 1 000 cycles per hour at AC-1 maximum. For DC switching at 24 V, the maximum permissible current is 0.016 A — this is a signal-level rating, not for power DC loads. The contactor is built for AC motor and resistive loads; the DC curve drops sharply as voltage rises.

Frequently asked questions

What are the key dimensions for panel layout?

Width 71 mm, height 85 mm, depth 101 mm. Side-by-side mounting requires a 6 mm air gap at the side. Mounts on 35 mm DIN rail per EN 50022.

What is the coil voltage and contact configuration?

24 VDC coil. Three instantaneous NO main contacts. Auxiliary contacts rated 20 A per NC and per NO contact.

What is the operating temperature range?

During operation -25 to +60 °C. Storage -55 to +80 °C. Maximum altitude 2 000 m.

MPN