Skip to main content
Siemens 3RT1926-2ED31 — Contactors

Siemens 3RT1926-2ED31 SIRIUS auxiliary switch

MPN3RT1926-2ED31
Active

Siemens SIRIUS auxiliary switch, 3RT1926-2ED31, ON-delay adjustable 5…100 s, 200…240 V AC coil, 3 A max contacts, clip-on mounting.

$40.64Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RT1926-2ED31 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz200 ... 240 V
3RT1926-2ED31 — Connection & Mounting
ParameterValue
Conductor cross-section, solid18 ... 14
Conductor cross-section, finely stranded w/ ferrule0.5 ... 2.5 m²
Mounting methodclip-on
3RT1926-2ED31 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-40 ... +85 °C
Installation altitude, max.2 000 m
3RT1926-2ED31 — Mechanical
ParameterValue
Width33 mm
Height46 mm
Depth73 mm

Product details

Time-delay auxiliary switch for SIRIUS contactors

The 3RT1926-2ED31: It clips onto the front of a SIRIUS contactor, so there's no extra DIN-rail space or wiring needed beyond the contactor's own terminals. The switch contacts are rated for 3 A maximum, and at 24 V they handle 1 A.

The 3 A maximum contact rating is the absolute ceiling — at 250 V AC the contacts are rated 0.1 A, at 125 V it's 0.2 A. That's typical for a signal-level auxiliary block driving a PLC input or a smaller relay coil, not a power circuit. The adjustable delay (5…100 s) lets you sequence a starter or interlock without a separate timer module — useful when you need a staggered motor start or a purge delay before the main contactor pulls in. The recovery time is 150 ms, so after the delay expires and the contacts reset, you can re-trigger the timer after that window.

Mounting and wiring in the panel

It clips directly onto a SIRIUS contactor — no tools, no extra DIN-rail footprint. Terminals accept 2x solid or stranded AWG 20…14 — standard control wiring. The housing is 33 mm wide, 46 mm tall, 73 mm deep, so it adds about 33 mm to the contactor's width. Basic insulation and pollution degree 3 mean it's rated for the usual industrial panel environment, but not for direct line-voltage isolation.

Current-production status per the manufacturer's record. No official successor or cross-reference on file.

Frequently asked questions

What are the time delay settings for Siemens 3RT1926-2ED31?

The adjustable ON-delay is set from 5 to 100 s. After the delay expires and the contacts reset, the recovery time is 150 ms before the timer can be re-triggered.

Is 3RT1926-2ED31 obsolete or is there a replacement?

The manufacturer's record shows current-production status. No official replacement or cross-reference is on file.

MPN
3RT1926-2ED31