Siemens 3RT2015-1AP02-ZW96 — Contactors

Siemens 3RT2015-1AP02-ZW96 SIRIUS Contactor, Size S00, 24 VD

MPN3RT2015-1AP02-ZW96
Active

Siemens SIRIUS power contactor, size S00, 3RT2015-1AP02-ZW96, 24 VDC coil, screw-type terminals, snap-on DIN rail mounting, 45 mm width.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RT2015-1AP02-ZW96 — Identification
ParameterValue
Contactor frame sizeS00
3RT2015-1AP02-ZW96 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V6.5 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V0.75 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2015-1AP02-ZW96 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.25
Rated value @ 50 Hz230 V
3RT2015-1AP02-ZW96 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2015-1AP02-ZW96 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 35A (690V,100kA), aM: 20A (690V,100kA), BS88: 35A (415V,80kA)
Short-circuit coordination type 2, fusegG: 20A (690V,100kA), aM: 16A (690V, 100kA), BS88: 20A (415V, 80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2015-1AP02-ZW96 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid0.5 ... 4 mm²
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Side-by-side mountingYes
3RT2015-1AP02-ZW96 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2015-1AP02-ZW96 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2015-1AP02-ZW96 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth73 mm
3RT2015-1AP02-ZW96 — Specifications
ParameterValue
At AC7 ... 13 ms

Product details

SIRIUS Size S00 Power Contactor

The 58 mm height and 73 mm depth leave room for side-by-side ganging at the standard 6 mm spacing.

Switching Capacity and Duty Cycles

This contactor switches 10 A at 24 V rated value, dropping to 2 A at 48 V and 60 V, 1 A at 110 V, 0.9 A at 125 V, 0.3 A at 220 V, and 3 A at 400 V. The 440 V rated value is 0.14 A — so if you're switching a 440 V signal, keep the load light. Mechanical life is typical at 30,000,000 operations. Maximum switching frequency varies by duty: 1,000 cycles/hour at AC-1, 750 at AC-2 and AC-3, and 250 at AC-4. The AC-3e rating matches the 750 cycles/hour mark.

Wire acceptance covers 0.5 to 4 mm² solid or stranded, with dual-wire options up to 2x 4 mm².

Frequently asked questions

What is the switching capacity at 24 VDC for this contactor?

It switches 10 A at 24 V rated value.

Where can I buy 3RT2015-1AP02-ZW96 and get current pricing?

This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

Will 3RT2015-1AP02-ZW96 drop into a panel specified around 3RT2015-1AV02 without rewiring?

Both are Size S00 SIRIUS contactors with the same 45 mm width and DIN rail mounting, so the mechanical footprint is identical. The main difference is the coil voltage — this unit uses a 24 VDC coil, while the 1AV02 variant uses a different coil voltage. Verify the coil supply before swapping.

MPN
3RT2015-1AP02-ZW96