Skip to main content
Siemens 3RT2015-1AP62 — Contactors

Siemens 3RT2015-1AP62 SIRIUS Power Contactor, Size S00, 45 m

MPN3RT2015-1AP62
Active

Siemens SIRIUS power contactor, Size S00, 3RT2015-1AP62, 45 mm width, screw-type coil terminals, auxiliary switch included.

$16.51Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT2015-1AP62 — Identification
ParameterValue
Contactor frame sizeS00
3RT2015-1AP62 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V6.5 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V0.75 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2015-1AP62 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.24
Rated value @ 50 Hz220 V
3RT2015-1AP62 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2015-1AP62 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 35A (690V,100kA), aM: 20A (690V,100kA), BS88: 35A (415V,80kA)
Short-circuit coordination type 2, fusegG: 20A (690V,100kA), aM: 16A (690V, 100kA), BS88: 20A (415V, 80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2015-1AP62 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid0.5 ... 4 mm²
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes
3RT2015-1AP62 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2015-1AP62 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2015-1AP62 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth73 mm
3RT2015-1AP62 — Specifications
ParameterValue
At AC4 ... 15 ms

Product details

The contactor carries an integrated auxiliary switch (1 NO + 1 NC, typical for the S00 frame), with screw-type terminals on the coil and main circuits. The coil terminal type is screw-type, and the main and auxiliary terminals accept solid or stranded conductors from 0.5 to 4 mm² (single or doubled up to 2× 2.5 mm²). Mechanical service life is rated at 30,000,000 operations typical, and the operating temperature range is -25 to +60 °C, with storage from -55 to +80 °C.

The 3RT2015-1AP62 is rated for maximum switching frequencies depending on duty: 1,000 cycles/hour at AC-1 (resistive loads), 750 cycles/hour at AC-3 (standard motor starting), and 250 cycles/hour at AC-4 (plugging/inching). For AC-3e (enhanced motor starting) the limit is also 750 cycles/hour. These are the thermal limits of the contactor — exceeding them shortens life or causes welding. The auxiliary contact ratings are given for several voltages: 10 A at 24 V, 2 A at 48 V and 60 V, 1 A at 110 V, 0.9 A at 125 V, 0.3 A at 220 V, and 3 A at 400 V. These are the maximum continuous currents the auxiliary contacts can switch at those voltages — useful for sizing control circuits.

Frequently asked questions

What is the depth of 3RT2015-1AP62?

The depth is 73 mm.

What conductor sizes does the 3RT2015-1AP62 accept?

Solid or stranded conductors from 0.5 to 4 mm², and doubled conductors up to 2× 2.5 mm².

Will 3RT2015-1AP62 drop into a panel designed for 3RT2026-1AG20?

Both are Size S00 contactors on the same 45 mm DIN-rail footprint, so the mechanical fit is identical. The main difference is the coil voltage and auxiliary contact configuration — verify those against the panel schematic before substitution.

MPN
3RT2015-1AP62