Siemens 3RT2015-2AB02-ZX95 — Contactors

Siemens 3RT2015-2AB02-ZX95 SIRIUS Power Contactor, S00, 24 V

MPN3RT2015-2AB02-ZX95
Active

Siemens SIRIUS 3RT2015-2AB02-ZX95, size S00 power contactor, 24 VDC coil, spring-type terminals, 45 mm width, 73 mm depth.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RT2015-2AB02-ZX95 — Identification
ParameterValue
Contactor frame sizeS00
3RT2015-2AB02-ZX95 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V6.5 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V0.75 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2015-2AB02-ZX95 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.25
Rated value @ 50 Hz24 V
3RT2015-2AB02-ZX95 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2015-2AB02-ZX95 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 35A (690V,100kA), aM: 20A (690V,100kA), BS88: 35A (415V,80kA)
Short-circuit coordination type 2, fusegG: 20A (690V,100kA), aM: 16A (690V, 100kA), BS88: 20A (415V, 80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2015-2AB02-ZX95 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid0.5 ... 4 mm²
Conductor cross-section, solid or stranded2x (0,5 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Side-by-side mountingYes
3RT2015-2AB02-ZX95 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2015-2AB02-ZX95 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2015-2AB02-ZX95 — Mechanical
ParameterValue
Width45 mm
Height70 mm
Depth73 mm
3RT2015-2AB02-ZX95 — Specifications
ParameterValue
At AC7 ... 13 ms

Product details

It is rated for AC-3 switching duty at up to 750 operating cycles per hour, which means it handles motor loads like conveyors and pumps in a standard control panel without overheating the coil or contacts.

The AC-3 maximum switching rate of 750 1/h tells you this contactor is sized for frequent motor starting — think conveyor sections or pump cycles — without derating for thermal buildup. The AC-4 maximum of 250 1/h covers plugging and inching duty, so if your application reverses or jogs the motor, you stay within the contactor's thermal limit. Spring-type terminals on the magnet coil accept solid or stranded wire from 0.5 to 4 mm², and the main contacts accept 2x (0.5 to 4 mm²) solid or stranded. The contactor's typical mechanical life of 30,000,000 operations means it outlasts most machinery rebuild cycles.

Frequently asked questions

Who supplies 3RT2015-2AB02-ZX95 and how is it quoted for volume purchases?

This part is sourced through independent distribution channels and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time — no stock count or price is listed here.

Will 3RT2015-2AB02-ZX95 drop into a panel that was specified around 3RT2015-2AP02 without rewiring?

The 3RT2015-2AP02 uses a different coil voltage or terminal configuration (the evidence does not detail the exact difference), so verify the coil rating and terminal type before substituting. The S00 frame size and DIN-rail mounting are shared, but the spring-type terminals on this variant may require a different wiring preparation than screw terminals on the other.

What is 3RT2015-2AB02-ZX95's listed depth (73 mm) on this component line?

The depth is 73 mm, which is the dimension from the mounting rail to the furthest protruding point of the contactor body. This fits standard 80 mm deep enclosures with room for wiring.

What is 3RT2015-2AB02-ZX95's listed solid (0.5... 4 mm²) on this component line?

The spring-type terminals accept solid wire from 0.5 to 4 mm². For stranded wire, the same range applies. The main contacts accept 2x (0.5 to 4 mm²) solid or stranded.