Siemens 3RT2015-2AK61-1AA0 SIRIUS Power Contactor, Size S00,

MPN3RT2015-2AK61-1AA0
Active

Siemens SIRIUS 3RT2015-2AK61-1AA0, power contactor, size S00, spring-type terminals, 73 mm depth, 45 mm width, 10 A at 24 V rated value.

$17.78Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT2015-2AK61-1AA0 — Identification
ParameterValue
Contactor frame sizeS00
3RT2015-2AK61-1AA0 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V6.5 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V0.75 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2015-2AK61-1AA0 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.24
Rated value @ 50 Hz110 V
3RT2015-2AK61-1AA0 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2015-2AK61-1AA0 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 35A (690V,100kA), aM: 20A (690V,100kA), BS88: 35A (415V,80kA)
Short-circuit coordination type 2, fusegG: 20A (690V,100kA), aM: 16A (690V, 100kA), BS88: 20A (415V, 80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2015-2AK61-1AA0 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid0.5 ... 4 mm²
Conductor cross-section, solid or stranded2x (0,5 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes
3RT2015-2AK61-1AA0 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2015-2AK61-1AA0 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2015-2AK61-1AA0 — Mechanical
ParameterValue
Width45 mm
Height70 mm
Depth73 mm
3RT2015-2AK61-1AA0 — Specifications
ParameterValue
At AC4 ... 15 ms

Product details

Siemens 3RT2015-2AK61-1AA0 — SIRIUS Power Contactor, Size S00 with Spring-Terminals

The spring-type terminals on the magnet coil and main contacts accept solid or stranded wire from 0.5 to 4 mm², including dual-wire entry up to 2x (0.5...4 mm²), which speeds panel wiring compared to screw-clamp variants. Rated operating current is 10 A at 24 V (AC-1 / AC-3 duty typical for this frame). The contactor includes an integrated auxiliary switch, eliminating the need for a separate add-on block for basic feedback or status signaling. Switching frequency limits are duty-dependent: up to 1,000 cycles/hour in AC-1 (resistive loads), 750 cycles/hour in AC-2 and AC-3 (motor starting/running), and 250 cycles/hour in AC-4 (plugging or inching). For AC-3e (enhanced motor rating) the limit is also 750 cycles/hour. These figures define the thermal capability of the contactor in continuous cycling applications — a line running frequent start/stop cycles should stay within the AC-3 or AC-3e ceiling.

The contactor is rated for standing vertical mounting on a horizontal surface. These ensure adequate airflow and arc-quenching space — tighten the panel layout to these minimums, not the DIN-rail edge. Dimensions are 73 mm depth, 45 mm width, and 70 mm height. The 45 mm width matches the standard S00 footprint, so it occupies four 11.25 mm DIN-rail positions (or one 45 mm wide slot in a modular enclosure).

Mechanical life of the contactor typical is 30,000,000 operations — this is the no-load mechanical endurance, not the electrical endurance under load. Electrical life depends on the switching duty and load current; for motor loads at rated current expect substantially fewer cycles, but the mechanical figure confirms the frame is built for high-cycle applications like conveyor or pump panels.

Frequently asked questions

How do I get current pricing and availability for 3RT2015-2AK61-1AA0?

Submit an RFQ through this listing. The part is sourced and quoted to order through independent distribution, with availability and current pricing confirmed at quote time — no stock count or price is published here.

Will 3RT2015-2AK61-1AA0 drop into a panel specified around 3RT2015-2AP01 without rewiring?

Both are Size S00 contactors with the same 45 mm width and DIN-rail mounting, so the mechanical fit is identical. The key difference is the coil termination: 3RT2015-2AK61-1AA0 uses spring-type terminals, while the 2AP01 variants use screw-type terminals. If the panel wiring was landed on screw clamps, the spring terminal version will require a different wiring method — no tool change, but the wire entry and clamping action differ. The auxiliary switch and main contact ratings are functionally equivalent for most motor loads.

What is 3RT2015-2AK61-1AA0's listed depth?

The depth is 73 mm, with a width of 45 mm and height of 70 mm.

What wire sizes does the spring terminal accept?

Solid or stranded wire from 0.5 to 4 mm², and dual-wire entry up to 2x (0.5...4 mm²). The spring-type terminals on the magnet coil and main contacts accept this range without ferrules for stranded wire.

MPN