Skip to main content
Siemens 3RT2015-2AV02 — Contactors

Siemens 3RT2015-2AV02 SIRIUS Power Contactor, Size S00, 24V

MPN3RT2015-2AV02
Active

Siemens SIRIUS power contactor, Size S00, 24 V DC coil, spring-type terminals, screw and snap-on mounting onto 35 mm DIN rail per DIN EN 60715, auxiliary switch included.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT2015-2AV02 — Identification
ParameterValue
Contactor frame sizeS00
3RT2015-2AV02 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V6.5 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V0.75 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2015-2AV02 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.25
Rated value @ 50 Hz400 V
3RT2015-2AV02 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2015-2AV02 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 35A (690V,100kA), aM: 20A (690V,100kA), BS88: 35A (415V,80kA)
Short-circuit coordination type 2, fusegG: 20A (690V,100kA), aM: 16A (690V, 100kA), BS88: 20A (415V, 80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2015-2AV02 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid0.5 ... 4 mm²
Conductor cross-section, solid or stranded2x (0,5 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes
3RT2015-2AV02 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2015-2AV02 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2015-2AV02 — Mechanical
ParameterValue
Width45 mm
Height70 mm
Depth73 mm
3RT2015-2AV02 — Specifications
ParameterValue
At AC4 ... 15 ms

Product details

The coil is 24 V DC, rated at 10 A — that's the hold current at nominal voltage, not the switching current. Spring-type terminals on the magnet coil mean no tool needed for the control wiring; the main contacts use screw terminals accepting 0.5 to 4 mm² solid or stranded.

Size S00 — what the footprint buys you

At 45 mm wide, 70 mm tall, and 73 mm deep, this contactor fits the standard S00 envelope — the same footprint as the 3RT2015-2AP02 and -2AP01 siblings. The mounting position is flexible: +/-180° rotation on a vertical surface, and can be tilted forward/backward by +/-22.5° on vertical mounting, which helps in tight enclosures or angled gland plates. Clearance spacing is modest: 10 mm upwards and forwards, 10 mm downwards, 6 mm at the side. That keeps the panel fill factor reasonable even with several contactors ganged on the same DIN rail.

Switching duty and auxiliary contact

Rated for AC-1 (resistive) at 1,000 operations per hour maximum, AC-2 and AC-3 (motor starting) at 750 ops/h, and AC-4 (plugging/inching) at 250 ops/h. Arcing time runs 10 to 15 ms at AC, and the contactor's typical mechanical life is 30 million operations — that's the mechanical endurance, not the electrical life under load, which will be lower depending on the switching category.

Environmental range and wiring

Operates from -25 to +60 °C ambient; storage range is -55 to +80 °C. The main contact terminals accept 2x (0.5 to 4 mm²) solid or stranded — fine for panel wiring with standard ferrules.

Frequently asked questions

Where can I buy the 3RT2015-2AV02?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment.

What is the closest functional second-source to the 3RT2015-2AV02?

The 3RT2015-2AP02 is a close sibling — same Size S00 frame, same DIN rail mount, same spring-type coil terminals. The difference is the coil voltage: the -2AP02 uses a different AC/DC coil rating. Verify coil voltage compatibility before substituting.

Will the 3RT2015-2AV02 drop into a panel specified for the 3RT2015-2AP02 without rewiring?

Yes, the mechanical footprint is identical — both are Size S00 with the same 45x70x73 mm envelope and DIN rail mounting. The main power wiring is interchangeable. The only difference is the coil voltage; rewire the control circuit if the coil ratings differ.

What compliance documentation does Siemens provide for the 3RT2015-2AV02?

Siemens SIRIUS contactors typically carry UL, CSA, CE, and IEC certifications, and are RoHS and REACH compliant. Specific documentation (declarations of conformity, certificates) is available on request at quote time.

MPN
3RT2015-2AV02