Skip to main content
Siemens 3RT2015-2UB41 — Contactors

Siemens 3RT2015-2UB41 SIRIUS Power Contactor, 24 VDC, S00

MPN3RT2015-2UB41
Active

Siemens SIRIUS power contactor, 3RT2015-2UB41, size S00, 24 V DC coil, spring-type terminals, 45 mm width, 73 mm depth.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT2015-2UB41 — Identification
ParameterValue
Contactor frame sizeS00
3RT2015-2UB41 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V6.5 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V0.75 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2015-2UB41 — Control & Coil
ParameterValue
Control supply voltage typeDC
3RT2015-2UB41 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2015-2UB41 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 35A (690V,100kA), aM: 20A (690V,100kA), BS88: 35A (415V,80kA)
Short-circuit coordination type 2, fusegG: 20A (690V,100kA), aM: 16A (690V, 100kA), BS88: 20A (415V, 80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2015-2UB41 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid0.5 ... 4 mm²
Conductor cross-section, solid or stranded2x (0,5 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes
3RT2015-2UB41 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
3RT2015-2UB41 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2015-2UB41 — Mechanical
ParameterValue
Width45 mm
Height70 mm
Depth73 mm

Product details

SIRIUS S00 power contactor — 24 V DC coil, spring terminals

Its 24 V DC coil and spring-type terminal connections on the magnet coil make it a fit for modern panels where wiring speed and vibration resistance matter. The contactor carries an auxiliary switch and is rated for main contact switching at 20–12 A.

Wiring and conductor range

The spring-type terminals eliminate the need for screwdriver torque checks — strip, insert, done. This matches typical panel-building practice for control circuits up to 4 mm².

Switching performance and operating rates

Operating rates vary by duty: 1,000 cycles/hour at AC-1, 750 cycles/hour at AC-2, AC-3, and AC-3e, and 250 cycles/hour at AC-4. DC switching time is 7–13 ms. The coil hold-in factor is rated at 0.8 initial, 1.1 full-scale. These figures matter for high-cycle applications like conveyor or pump cycling — AC-4 rate limits plugging and inching duty.

The auxiliary switch is rated for switching at various control voltages: 10 A at 24 V, 2 A at 48 V, 2 A at 60 V, 1 A at 110 V, 0.9 A at 125 V, 0.3 A at 220 V, and 3 A at 400 V. At 230 V it carries a 0.75 hp motor rating. These are the numbers to check when the auxiliary feeds a PLC input or another contactor coil.

Frequently asked questions

Where can I buy 3RT2015-2UB41 and get a price?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for your quantity.

Will 3RT2015-2UB41 drop into a panel specified for 3RT2015-2HB41?

Both are S00 frame contactors on the same 45 mm DIN footprint with identical mounting clearances. The difference is the coil voltage: the 2UB41 uses 24 V DC; the 2HB41 uses a different coil. If the panel wiring and control voltage match 24 V DC, it is a direct mechanical swap — no rewiring of the main power path needed.

What is the depth of 3RT2015-2UB41?

73 mm. That is the dimension from the DIN rail mounting surface to the front of the contactor body — relevant for enclosure depth planning.

What conductor sizes does the spring terminal accept?

Solid or stranded wire from 0.5 to 4 mm², and dual conductors of the same range. No ferrule required for stranded — the spring cage handles it directly.

MPN
3RT2015-2UB41