Specifications

3RT2016-1AH01 — Identification
ParameterValue
Contactor frame sizeS00
3RT2016-1AH01 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V1 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2016-1AH01 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.25
Rated value @ 50 Hz48 V
3RT2016-1AH01 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2016-1AH01 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 35A (690V,100kA), aM: 20A (690V,100kA), BS88: 35A (415V,80kA)
Short-circuit coordination type 2, fusegG: 20A (690V,100kA), aM: 16A (690V, 100kA), BS88: 20A (415V, 80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2016-1AH01 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid0.5 ... 4 mm²
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes
3RT2016-1AH01 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2016-1AH01 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2016-1AH01 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth73 mm
3RT2016-1AH01 — Specifications
ParameterValue
At AC4 ... 15 ms

Product details

Contactor for panel builders and MRO spares

Rated operational current at 24 V is 10 A, which is the headline figure for this contactor's switching capacity at the coil voltage. The contactor is rated for switching frequencies up to 1000 cycles per hour in AC-1 duty (resistive loads) and 750 cycles per hour in AC-3 duty (motor starting). The 45 mm width and 58 mm height fit standard DIN-rail spacing, with 73 mm depth allowing clearance for wiring.

Frequently asked questions

What is the closest functional second-source for the 3RT2016-1AH01?

The 3RT2016-1AB01-ZX95 is a close functional peer, but verify the coil voltage and any special features (ZX95 suffix indicates a special version) before substituting without rewiring.

What is the depth of the 3RT2016-1AH01?

The depth is 73 mm.

What is the solid conductor cross-section range for the 3RT2016-1AH01?

The solid conductor cross-section range is 0.5 to 4 mm².

Will the 3RT2016-1AH01 drop into a panel specified around the 3RT2016-1AB01-ZX95 without rewiring?

Both are Size S00 contactors with screw terminals and share the same mounting footprint on 35 mm DIN rail. However, the coil voltage differs: the -1AH01 uses a 24 VDC coil. Verify the coil voltage matches your control circuit before direct replacement.

MPN
3RT2016-1AH01