Skip to main content
Siemens 3RT2016-1AK61 — Contactors

Siemens 3RT2016-1AK61 SIRIUS Power Contactor, Size S00, 24 V

MPN3RT2016-1AK61
Active

Siemens SIRIUS 3RT2016-1AK61 power contactor, size S00, 24 VDC coil, screw-type terminals, 45 mm wide, 73 mm depth, 58 mm height.

$17.78Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT2016-1AK61 — Identification
ParameterValue
Contactor frame sizeS00
3RT2016-1AK61 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V1 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2016-1AK61 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.24
Rated value @ 50 Hz110 V
3RT2016-1AK61 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2016-1AK61 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 35A (690V,100kA), aM: 20A (690V,100kA), BS88: 35A (415V,80kA)
Short-circuit coordination type 2, fusegG: 20A (690V,100kA), aM: 16A (690V, 100kA), BS88: 20A (415V, 80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2016-1AK61 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid0.5 ... 4 mm²
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes
3RT2016-1AK61 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2016-1AK61 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2016-1AK61 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth73 mm
3RT2016-1AK61 — Specifications
ParameterValue
At AC4 ... 15 ms

Product details

An integrated auxiliary switch is included on the front.

Frame size S00 keeps the contactor at 45 mm wide, 58 mm tall, and 73 mm deep — it snaps onto a 35 mm DIN rail per DIN EN 60715 and fits standard 45 mm-wide modular spacing.

Switching frequency and auxiliary contact ratings

Maximum switching rate depends on duty: AC-1 (resistive) allows 1,000 operations per hour; AC-2 and AC-3 (motor starting) both allow 750 per hour; AC-4 (plugging/inching) is limited to 250 per hour. The auxiliary contact is rated for 10 A at 24 V, 2 A at 48/60 V, 1 A at 110 V, 0.9 A at 125 V, 0.3 A at 220 V, 3 A at 400 V, and 0.2 A at 440 V — these are the switching limits for control-circuit loads like PLC inputs or relay coils.

Frequently asked questions

What are the key dimensions for panel layout?

Width is 45 mm, height 58 mm, depth 73 mm. It mounts on 35 mm DIN rail per DIN EN 60715, with clearance of 10 mm upwards, 10 mm downwards, 6 mm at the sides, and 10 mm forward.

What wire sizes does the screw terminal accept?

Solid or stranded wire from 0.5 to 4 mm². For two conductors: 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or 2x 4 mm².

What is the operating temperature range?

During operation: -25 to +60 °C. During storage: -55 to +80 °C.

MPN
3RT2016-1AK61