Skip to main content
Siemens 3RT2016-1AK61-ZW96 — Contactors

Siemens 3RT2016-1AK61-ZW96 SIRIUS S00 Power Contactor, 24 VD

MPN3RT2016-1AK61-ZW96
Active

Siemens SIRIUS S00 power contactor, 3RT2016-1AK61-ZW96, 24 VDC coil, screw-type terminals, 45 mm width, current production.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT2016-1AK61-ZW96 — Identification
ParameterValue
Contactor frame sizeS00
3RT2016-1AK61-ZW96 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V1 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2016-1AK61-ZW96 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.24
Rated value @ 50 Hz110 V
3RT2016-1AK61-ZW96 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2016-1AK61-ZW96 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 35A (690V,100kA), aM: 20A (690V,100kA), BS88: 35A (415V,80kA)
Short-circuit coordination type 2, fusegG: 20A (690V,100kA), aM: 16A (690V, 100kA), BS88: 20A (415V, 80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2016-1AK61-ZW96 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid0.5 ... 4 mm²
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes
3RT2016-1AK61-ZW96 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2016-1AK61-ZW96 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2016-1AK61-ZW96 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth73 mm
3RT2016-1AK61-ZW96 — Specifications
ParameterValue
At AC4 ... 15 ms

Product details

The auxiliary switch is built in, with contacts rated for switching loads at voltages from 24 V (10 A) up to 440 V (0.2 A), covering typical control-circuit and signal-level applications.

Duty-cycle limits and thermal envelope

Maximum switching frequency depends on the load category: 1 000 operations per hour under AC-1 resistive loads, 750/h under AC-2 or AC-3 motor duty, and 250/h under the severe AC-4 plugging/reversing cycle.

Wiring and clearance

Screw terminals accept solid or stranded wire from 0.5 mm² up to 4 mm², with dual-wire capacity for 2x (0.5…1.5 mm²), 2x (0.75…2.5 mm²), or 2x 4 mm². Minimum clearance around the contactor: 10 mm above, below, and forward; 6 mm at the sides. Overall dimensions are 58 mm high, 45 mm wide, and 73 mm deep — the S00 frame size keeps it compact for high-density panel layouts.

Frequently asked questions

Where can I buy 3RT2016-1AK61-ZW96 and how do I get a price?

The part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current availability and pricing.

What are the key dimensions of 3RT2016-1AK61-ZW96?

Height 58 mm, width 45 mm, depth 73 mm — the S00 frame size. Minimum clearance: 10 mm above/below/forward, 6 mm at the sides.

What wire sizes does the screw terminal accept?

Solid or stranded 0.5…4 mm² single wire, or dual wires: 2x (0.5…1.5 mm²), 2x (0.75…2.5 mm²), or 2x 4 mm².

What is the maximum switching frequency for motor duty?

750 operations per hour under AC-2 or AC-3 duty; 250/h under AC-4 plugging/reversing. For resistive AC-1 loads, 1 000/h.

MPN
3RT2016-1AK61-ZW96